60

Response

OK

OK or ERROR

Default

0000

Range

0000 – FFFF

7.4.5

AT+POWER or AT+PW

Description

Get/Set the TX power at which the RF module transmits conducted power.

Execute

AT+POWER?

AT+POWER=

Response

OK

OK or ERROR

Default

8

Range

-43 – 8

7.4.6

AT+STACK or AT+ZS

Description

Get/Set the ZigBee stack profile value. This value must be set the same on all

devices that should join the same network. (0: Network specific, 1: ZigBee, 2:

ZigBee Pro)

Execute

AT+STACK?

AT+STACK=

Response

OK

OK or ERROR

Default

2

Range

0 – 2

* Default value changed 2 from 0

7.4.7

AT+NODENAME or AT+NN

Description

Get/Set the node name. It can be used to make a clear distinction role or

functionality of local node from others.

Execute

AT+NODENAME?

AT+NODENAME=

Response

OK

OK or ERROR

Default

ProBee-HAxx

Range

Up to 16 characters

7.5

Network Formation and Join

7.5.1

AT+ASCAN or AT+AS

Description

Perform a scanning for existing network. It can take up to 5 seconds. (CAUTION:

It is possible to cause a link error if a node is a parent of an end-device.)

Execute

AT+ASCAN

AT+ASCAN=

Response

||||