SM3300 INTERFACES

Nov.2012, Preliminary version

SPECIFICATIONS

Page 1 - 5

Isolated Contacts

Specifications

Typical Applications

• Trigger an external safety alarm

• Switch the output On/Off with a remote 24Vdc signal

• Interact in automated processes

• Using a floating signal for triggering the Interlock function

Re lay con tacts 1... 4

Con tact volt age
Con tact current
Max i mum switch ing ca pac ity

60 V

2 A

60 W

Float ing In ter lock

Open cir cuit voltage

5 V

Float ing En able

Nom i nal in put volt age
In put volt age range
In put impedance

24VDC

15 - 30VDC

12kOhm

In su la tion
prog. con nec tors - in ter nal cir cuits
prog. con nec tors - earth

1000 VDC Re in forced iso la tion acc. EN60950-1 / EN61010-1

max. 60VDC

Safety

EN 60950 / EN 61010

Op er at ing Tem per a ture

− 20 to + 50 °C

Hu mid ity

max. 95% RH, non con dens ing, up to 40 °C
max. 75% RH, non con dens ing, up to 50 °C

Stor age tem per a ture

− 40 to + 85 °C

Mount ing

Pluggable, SM3300 in ter face slots 1, 2, 3 and 4.

See para graph 'Hard ware In stal la tion' in this man ual.

Max i mum 4 per unit.

Pro gram ming con nec tor

Re lay 1 & 2, via a 6 pole push wire or so-called push in con nec tor.

Re lay 3 & 4, via a 6 pole push wire / push in con nec tor.

In ter lock and En able via a 3 pole push wire / push in con nec tor.

For all 3 con nec tors there's a con tra header sup plied.

Weight

0.14 kg