Specifications typical applications, Isolated analog controller interface – Powersolve SM3300 Interfaces User Manual
Page 2

SM3300 INTERFACES
Page 1 - 2
SPECIFICATIONS
Nov.2012, Preliminary version
An a log Pro gram ming
CV
CC
Pro gram ming in puts
in put range
ac cu racy
off set
temp. coeff. off set
in put im ped ance
0 - 5 V
± 0.2%
- 1 ... +1 mV (on 5V)
10 µV / °C
10 MOhm
0 - 5 V
± 0.2%
- 1 ... + 1 mV (on 5V)
10 µV / °C
10 MOhm
Mon i tor ing out put
out put range
ac cu racy
off set
temp. coeff. off set
out put im ped ance
0 - 5 V
± 0.2%
- 1... 1 mV (on 5V)
3 µV / °C
2 Ohm / max. 4 mA
- 5 V to + 5 V
± 0.2%
- 1... 1 mV (on 5V)
60 µV / °C
2 Ohm / max. 4 mA
Ref er ence volt age
on prog. con nec tor
V
ref
TC
5.114 V ± 15 mV (Ro = 2 Ohm, max. 4 mA)
20 ppm
+12 V out put
V
o
on prog. Con nec tor
I
max
R
o
12 V ± 0.2 V
0.2 A
5 Ohm
Sta tus out puts
CC - sta tus
LIM- sta tus
OT
- sta tus
PSOL
- sta tus
ACF
- sta tus
DCF
- sta tus
CC - op er a tion
5 V = logic 1 (R
o
= 500 Ohm)
CV or CC limit
5 V = logic 1 (R
o
= 500 Ohm)
Over Tem per a ture
5 V = logic 1 (R
o
= 500 Ohm)
Power Sink Over load
5 V = logic 1 (R
o
= 500 Ohm)
AC - Fail
5 V = logic 1 (R
o
= 500 Ohm)
DC - Fail
2
)
5 V = logic 1 (R
o
= 500 Ohm)
2
) out put volt age ± 5% be yond set point
Re mote Shut Down
with + 5V, 1 mA or re lay con tact
In su la tion
prog. con nec tor - in ter nal cir cuits
prog. con nec tor - earth
1000 VDC Re in forced iso la tion acc. EN60950-1 / EN61010-1
max. 60VDC
Safety
EN 60950 / EN 61010
Op er at ing Tem per a ture
− 20 to + 50 °C
Hu mid ity
max. 95% RH, non con dens ing, up to 40 °C
max. 75% RH, non con dens ing, up to 50 °C
Stor age tem per a ture
− 40 to + 85 °C
Mount ing
Pluggable, SM3300 in ter face slots 2, 3, 4.
See para graph 'Hard ware In stal la tion' in this man ual.
Note1: can not be plugged in slot1
Note2: max 1pcs MOD INT ANA per unit.
Pro gram ming con nec tor
15 pole D-con nec tor (fe male)
Weight
0.14 kg
Specifications
Typical Applications
• Analog programming of voltage and current
• Remote monitoring of the status signals: OverTemp, Limit, PowerSink OverLoad
• Analog monitoring of voltage and current
• Remote Shut down of the power output using a 5V signal
Isolated Analog Controller interface