Powersolve Power Sink Option for SM1500 User Manual
1500 with power sink option
Datasheet - SM1500 Power Sink
SM35-45 with Power Sink Op tion
Cur rent – 20 A means the load de liv ers 20 A to
the power sup ply (sink op er a tion)
Up per trace: out put volt age
Lower trace: out put cur rent
(cur rent switch ing from +20 A to –20 A at Vo=6 V)
SM35-45 with out Power Sink Op tion
The out put volt age is out of con trol when
the out put cur rent is neg a tive
Up per trace: out put volt age
Lower trace: out put cur rent
(cur rent switch ing from +20 A to –20 A at Vo=6 V)
The power sink option permits the power supply to absorb
bursts of power fed back to the unit. An internal module senses
the status of power supply and sinks current across the output
terminals, thus maintaining a constant output voltage.
The Power Sink Option allows a faster response when the
power supply is step programmed to a lower voltage at small
load conditions.
•
Can absorb 200 W peak power
•
Maintains output voltage setting regardless output power
is positive or negative (source and sink)
•
Ideal solution for supplying electric motors with
PWM-speed control. These systems often return power to
the power supply during a braking action
•
Ideal solution for ATE systems requiring fast down
programming at no load conditions
•
Generation Automotive waveforms (fast)
SM 15-100
P202
SM 35-45
P203
SM 52-30
P204
SM 52-AR-60
P205
SM 70-22
P206
SM
1500
with Power Sink Option
2 Quadrant operation: Source and Sink