Powersolve SM3300 Interfaces User Manual
Page 4

SM3300 INTERFACES
Page 1 - 4
SPECIFICATIONS
Nov.2012, Preliminary version
Digital User I/O
Specifications
Typical Applications
• Hardware triggering of sequences
• Stand-alone automation
• Interaction with other equipment
• Safety or Alarm indications
Logic in puts 1... 8
In put range
In put im ped ance
Load cur rent +5V
2 - 30V
Rin = 22kOhm
100mA
Logic out puts 1 ... 8
Out put type
Out put im ped ance
Open Drain (True = 0V, False = open)
7 Ohm (max 30V/200mA)
In su la tion
prog. con nec tors - in ter nal cir cuits
prog. con nec tors - earth
1000 VDC Re in forced iso la tion acc. EN60950-1 / EN61010-1
max. 60VDC
Safety
EN 60950 / EN 61010
Op er at ing Tem per a ture
− 20 to + 50 °C
Hu mid ity
max. 95% RH, non con dens ing, up to 40 °C
max. 75% RH, non con dens ing, up to 50 °C
Stor age tem per a ture
− 40 to + 85 °C
Mount ing
Pluggable, SM3300 in ter face slots 1, 2, 3 and 4.
See para graph 'Hard ware In stal la tion' in this man ual.
Max i mum 4 per unit.
Pro gram ming con nec tor
User Out puts via 15 pole D-con nec tor High Den sity (fe male),
User In puts via 15 pole D-con nec tor High Den sity (fe male).
Weight
0.14 kg