beautypg.com

Powersolve JB800 Series User Manual

Ac-dc converter, Features

background image

Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England

Tel: 01635 521858 Fax: 01635 523771 Email: [email protected]

AC-DC Converter

Input Voltage

90-264Vac full range, 47-63Hz

Inrush Current

70A max. @ 230Vac with full load output, cold start

PFC

Active Power Factor Correction meets EN61000-3-2 class D

Transient Response

Returns to within 1% in less than 2.5mS for 50% load change & peak transient does not exceed 5%

Overshoot

Turn-on & turn-off overshoot <5% of nominal voltage

Efficiency

70% for 3.3V, 75% for 5V, 80% for 12V and 83% min. for other outputs @ 230Vac input and full load

Turn On Delay

1 second max. at 230Vac input

Hold Up Time

20mS min. at 80% of full load

Adjustability

Output user adjustable ±5% min.

Remote On/Off

Designated as RSW on CN3, requires a low signal to inhibit output

Remote Sense

Designated as RS+ and RS- on CN3 , voltage compensates for up to 0.5V line drop
(NOT available for current sharing models)

LED Display

Bi-colour LED1 emits Green for power on & Orange when protection is enabled
or RSW is applied with a low signal

Power Good

Designated as PG on CN3. TTL high 100-500mS after regulation and low at least 1mS before
loss of regulation for Power On reset signal

Current Sharing

Designated as CSH on CN3. Optional single wire forced current sharing function to enable up to
4 units to be connected in parallel with a 10% accuracy at full load

Current Monitor

Designated as CMN on CN3. A 0.5V - 3.0VDC output voltage to represent 0-100% of output current

Input Fusing Protection

T12A/250V fuse in the primary

Input Voltage Protection

Shuts down output when input is under 80Vac ±5Vac. Recovers when input above 86Vac.

Short Circuit Protection

Trip without damage and auto-recovery.

Over-Power Protection

Fold back mode 110-140% and auto-recovery

Over-Voltage Protection

Output latches off when output exceeds 130% of maximum. Recycle AC input to recover

Over-Temperature Protection Unit protected against excessive operating ambient @85°C and auto-recovery
Operating Temperature

0 to 70°C ambient. De-rating at 2.5%/°C from 50°C to 70°C

Storage Temperature

-20 to 85°C

Operating Humidity

5% to 90% RH Non-condensing

Storage Humidity

5% to 95% RH Non-condensing

Vibration

5 - 50Hz, acceleration 7.35m/s*s on X, Y and Z axis

Emissions

FCC Part 15, CISPR 22 class B, conducted

Safety Regulation

Approved to UL60950-1, CSA C22.2 No. 60950-1-03, TUV EN60950-1,
CE Mark (LVD) EN61000-3-2, 3 & IEC61000-4 Series Regulations and CB

Leakage Current

3.5mA max @240Vac

HI-POT Withstand Voltage

1500Vac input line to chassis (10mA DC cut off current); 3000Vac primary to secondary windings;
1500Vac primary to core. All for 3 secs.

Grounding Test

Apply 25A from earth pin of input connector to far most earth point. Max. allowable resistance 0.1Ω

MTBF

100,000 Hrs (according to MIL-HBK-217F) at 30°C

Enclosure

E Type: 9.17(L) x 4.25(W) x 2.5(H) inches
U Type: 8(L) x 4.33(W) x 2.5(H) inches
F Type: 8(L) x 4.33(W) x 3.4(H) inches

Cooling

E & F Type: built-in fan
U Type: 30CFM to achieve max. power

Weight

E & F Type: 1450g
U Type: 1350g

Electrical Specification

www.powersolve.co.uk

Features

Universal AC Input / Full Range

Optional N+1 Active Current Share

Power Factor Corrected to EN61000-3-2 class D

High Power Density (max. 9.1 watts per cubic inch)

Approved to UL/cUL/TUV/CB/CE & Class B emissions

U-Chassis & Enclosed with built-in fan options

JB500/JB600/JB750/JB800 Series
264-800W Active PFC
Single Output
(optional current share)

F-Type

E-Type

U-Type