Powersolve JB800 Series User Manual
Ac-dc converter, Features
Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England
Tel: 01635 521858 Fax: 01635 523771 Email: [email protected]
AC-DC Converter
Input Voltage
90-264Vac full range, 47-63Hz
Inrush Current
70A max. @ 230Vac with full load output, cold start
PFC
Active Power Factor Correction meets EN61000-3-2 class D
Transient Response
Returns to within 1% in less than 2.5mS for 50% load change & peak transient does not exceed 5%
Overshoot
Turn-on & turn-off overshoot <5% of nominal voltage
Efficiency
70% for 3.3V, 75% for 5V, 80% for 12V and 83% min. for other outputs @ 230Vac input and full load
Turn On Delay
1 second max. at 230Vac input
Hold Up Time
20mS min. at 80% of full load
Adjustability
Output user adjustable ±5% min.
Remote On/Off
Designated as RSW on CN3, requires a low signal to inhibit output
Remote Sense
Designated as RS+ and RS- on CN3 , voltage compensates for up to 0.5V line drop
(NOT available for current sharing models)
LED Display
Bi-colour LED1 emits Green for power on & Orange when protection is enabled
or RSW is applied with a low signal
Power Good
Designated as PG on CN3. TTL high 100-500mS after regulation and low at least 1mS before
loss of regulation for Power On reset signal
Current Sharing
Designated as CSH on CN3. Optional single wire forced current sharing function to enable up to
4 units to be connected in parallel with a 10% accuracy at full load
Current Monitor
Designated as CMN on CN3. A 0.5V - 3.0VDC output voltage to represent 0-100% of output current
Input Fusing Protection
T12A/250V fuse in the primary
Input Voltage Protection
Shuts down output when input is under 80Vac ±5Vac. Recovers when input above 86Vac.
Short Circuit Protection
Trip without damage and auto-recovery.
Over-Power Protection
Fold back mode 110-140% and auto-recovery
Over-Voltage Protection
Output latches off when output exceeds 130% of maximum. Recycle AC input to recover
Over-Temperature Protection Unit protected against excessive operating ambient @85°C and auto-recovery
Operating Temperature
0 to 70°C ambient. De-rating at 2.5%/°C from 50°C to 70°C
Storage Temperature
-20 to 85°C
Operating Humidity
5% to 90% RH Non-condensing
Storage Humidity
5% to 95% RH Non-condensing
Vibration
5 - 50Hz, acceleration 7.35m/s*s on X, Y and Z axis
Emissions
FCC Part 15, CISPR 22 class B, conducted
Safety Regulation
Approved to UL60950-1, CSA C22.2 No. 60950-1-03, TUV EN60950-1,
CE Mark (LVD) EN61000-3-2, 3 & IEC61000-4 Series Regulations and CB
Leakage Current
3.5mA max @240Vac
HI-POT Withstand Voltage
1500Vac input line to chassis (10mA DC cut off current); 3000Vac primary to secondary windings;
1500Vac primary to core. All for 3 secs.
Grounding Test
Apply 25A from earth pin of input connector to far most earth point. Max. allowable resistance 0.1Ω
MTBF
100,000 Hrs (according to MIL-HBK-217F) at 30°C
Enclosure
E Type: 9.17(L) x 4.25(W) x 2.5(H) inches
U Type: 8(L) x 4.33(W) x 2.5(H) inches
F Type: 8(L) x 4.33(W) x 3.4(H) inches
Cooling
E & F Type: built-in fan
U Type: 30CFM to achieve max. power
Weight
E & F Type: 1450g
U Type: 1350g
Electrical Specification
www.powersolve.co.uk
Features
•
Universal AC Input / Full Range
•
Optional N+1 Active Current Share
•
Power Factor Corrected to EN61000-3-2 class D
•
High Power Density (max. 9.1 watts per cubic inch)
•
Approved to UL/cUL/TUV/CB/CE & Class B emissions
•
U-Chassis & Enclosed with built-in fan options
JB500/JB600/JB750/JB800 Series
264-800W Active PFC
Single Output
(optional current share)
F-Type
E-Type
U-Type