beautypg.com

Powersolve TOP200 Series User Manual

Ac-dc power supplies, Features

background image

Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England

Tel: 01635 521858 Fax: 01635 523771 Email: [email protected]

AC-DC Power Supplies

TOP 200 Series, 200 Watt

Features

Highest power density in 127 x 76.2mm footprint

Supplies 200W with convection cooling

High efficiency of 90% typical

Operating temperature range of -25°C to +70°C

Compliance with EN 61000-3-2

Low leakage current

Safety class I and class II

Electrical Specification

Input voltage range

85-264Vac with derating at low mains input

Input Frequency

47-63Hz

EMI emission

EN 55022 class B, harmonic current EN 61000-3-2 class A

EMI immunity

EN 61000-4-2, -3, -4, -5, -6, -11

Output current limitation

120-150% of Iout max.

Short Circuit Protection

foldback, automatic recovery

Overvoltage protection

>150% of Vout nom. (12 & 15V models), >125% of Vout nom. (24 & 48V models)

Operating Temperature Range

-25°C to +70°C (convection cooling) (derate linearly to 80W at 70°C above 40°C)

Safety Approvals

cUL/UL 60950-1, IEC/EN 60950-1

Degree of protection

Class I, class II prepared with second fuse

Output Voltage and Current Ratings

MODEL

OUTPUT

OUTPUT

OUTPUT

RIPPLE &

LINE REG.

LOAD REG.

EFFICIENCY

POWER

VOLTAGE

CURRENT

NOISE

TOP 200-112

200W

12VDC

16A

120mV pk-pk max.

1.0%

1.0%

90%

TOP 200-115

200W

15VDC

13A

120mV pk-pk max.

1.0%

1.0%

90%

TOP 200-124

200W

24VDC

8.3A

120mV pk-pk max.

1.0%

1.0%

92%

TOP 200-148

200W

48VDC

4.2A

150mV pk-pk max.

1.0%

1.0%

92%

Mechanical & Connection Details

J1

Mating connector: Molex 09-50-3031

Crimp Terminal: Molex 08-52-0072

Pin

Function

1

AC in Live

2

AC in Neutral

PE

Mating connector: TAB-6.3 (¼”)

Protective Earth if used as safety class 1 unit

J2

Mating Connector: Molex 09-50-3061

Crimp Terminal: Molex 08-52-0072

Pin

SINGLE OUTPUT

1

+Vout

2

+Vout

3

+Vout

4

-Vout

5

-Vout

6

-Vout

J3

Mating Connector: Molex 22-01-2025

Crimp Terminal: 08-50-0032

Pin

Function

1

Contact

2

Current

Pin 1 connected to secondary ground will turn unit OFF
Output voltage may pulse to 20% of nominal output voltage
Pin 2 connected to ext. current source of 10mA will turn unit OFF
No pulsing of output voltage
Pin 1 & 2 open circuit: unit is ON

Dimensions in Inches (mm)