beautypg.com

Powersolve Power Sink Option for SM800 User Manual

800 with power sink option

background image

SM 7.5-80

P245

SM 18-50

P246

SM 70-AR-24

P247

SM 400-AR-4

P248

Datasheet - SM800 Power Sink

SM18-50 with Power Sink Op tion

Cur rent – 15 A means the load de liv ers 15 A to

the power sup ply (sink op er a tion)

Up per trace: out put volt age
Lower trace: out put cur rent

(cur rent switch ing from +15 A to –15 A at Vo=6 V)

SM18-50 with out Power Sink Op tion

The out put volt age is out of con trol when

the out put cur rent is neg a tive

Up per trace: out put volt age
Lower trace: out put cur rent

(cur rent switch ing from +15 A to –15 A at Vo=6 V)

SM70-AR-24

The power sink option permits the power supply to absorb
bursts of power fed back to the unit. An internal module senses
the status of power supply and sinks current across the output
terminals, thus maintaining a constant output voltage.

The Power Sink Option allows a faster response when the
power supply is step programmed to a lower voltage at small
load conditions.

Can absorb 140 W peak power

Maintains output voltage setting regardless output power
is positive or negative (source and sink)

Ideal solution for supplying electric motors with
PWM-speed control. These systems often return power to
the power supply during a braking action

Ideal solution for ATE systems requiring fast down
programming at no load conditions

Generation Automotive waveforms (fast)

SM

800

with Power Sink Option

2 Quadrant operation: Source and Sink

Unit 8A
Arnhem Road
Newbury. RG14 5RU

Tel: +44 (0) 1635 521858
Fax: +44 (0) 1635 523771
www.powersolve.co.uk

Models