beautypg.com

Powersolve PPS120 Series User Manual

Ac-dc converters

background image

Powersolve Electronics Ltd. Units 8A, Arnhem Road, Newbury, RG14 5RU. England

Tel:01635 521858 Fax: 01635 523771 Email: [email protected]

www.powersolve.co.uk

AC-DC Converters

PPS120 Series
90/120 Watts
Single, Dual, Triple & Quad Outputs

Features

Universal AC input

Built-in EMI filter

Optional 12V, 24V or 48V DC input

(Consult sales office for details)

Optional Cover

INPUT
Input range

90~264 VAC, universal

Frequency

47~63Hz

Inrush current

38A typical, Cold start @ 25°C, 115 VAC

Efficiency

65%~85% typical at full load

EMI filter

FCC Class B conducted, CISPR 22 Class B conducted, EN55022 class B Conducted

Line regulation

±0.5% typical

OUTPUT
Maximum power

120W with 30 CFM forced air. 90 Watts convection cooled. See power derating curve

Peak power

150 watts

Output adjustment

±10% on output 1

Hold-up time

10ms typical at full load and 115 VAC nominal line

Overload protection

Short circuit protection

Overvoltage protection

Main output 20% to 40% above nominal output

Ripple/Noise

±1% Max.@ full load

Peak power

150 watts

ENVIRONMENTAL
Operating temperature

0 to 50°C ambient; derate each output at 2.5% per degree from 50°C to 70°C

Humidity

Operating; non-condensing, 5% to 95%

Vibration

10~55 Hz at 1G 3 minutes period, 30 minutes along X, Y and Z axis

Storage temperature

-40 to 85°C

Temperature coefficient

±0.05% per degree C

MTBF demonstrated

>100,000 hours at full load and 25°C ambient conditions

EMI & EMC

FCC part 15, Class B
CISPR 22 / EN55022, Class B
VCCI, Class 2
CE, EN 61000-3-2 (Class A) and –3; EN 61000-4-2, -3,-4.-5,-6 and -11

Safety approval

UL, cUL, TUV EN60950

Electrical Specification

120W

90W

60W

30W

0W

60W

45W

Power Derating Curve

30 CFM Forced Air Cooling

010

20

30

40

50 60

70

Natural

Convection

Cooling

Output

Power

(Watts)

Ambient Temperature (°C)

Derate output power by 25%
when cover fitted