Powersolve CFM101S Series User Manual
Ac-dc converter, Features
Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England
Tel: 01635 521858 Fax: 01635 523771 Email: [email protected]
www.powersolve.co.uk
AC-DC Converter
CFM101S Series
100 Watt Open Frame
Single Output
Features
•
Universal input range 90-264Vac
•
Active PFC Function
•
2” x 4” (50.8 x 101.6mm) size
•
Efficiency to 85%
•
Continuous short circuit protection
•
Meets CISPR/FCC Class B, conducted
INPUT
Input Voltage Range
90 - 264VAC
Frequency
47 - 63Hz
Inrush Current
90A max. @ 240VAC
Conducted EMI
CISPR/FCC Class B
Isolation - Input/Output
4242VDC
Leakage Current
3.5mA max.
OUTPUT
Hold-up Time
18mS typ. @ 115Vac
Short Circuit Protection
Continuous
Temperature Coefficient
±0.05% / °C
ENVIRONMENTAL
Operating Temperature Range
0°C to +40°C
Storage Temperature Range
-20°C to +85°C
Cooling
Natural convection
Safety Approvals
cUL/UL 60950, TUV EN60950
GENERAL
Dimensions
101.6 x 50.8 x 27.94 mm
4.0 x 2.0 x 1.1 inches
Weight
150g
Electrical Specification
Typical at 25°C, nominal line and 75% load unless otherwise stated.
Output Voltage and Current Ratings
MODEL
OUTPUT
OUTPUT CURRENT
RIPPLE
VOLTAGE
LINE
LOAD
VOLTAGE
Min.
Max.
(mV pk-pk)
ACCURACY
REG.
REG.
CFM101S120
12V
0A
8.4A
1%
±1%
±0.5%
±1%
CFM101S150
15V
0A
6.7A
1%
±1%
±0.5%
±1%
CFM101S240
24V
0A
4.2A
1%
±1%
±0.5%
±1%
CFM101S480
48V
0A
2.1A
1%
±1%
±0.5%
±1%
NOTE:
1. Output noise and ripple measured with 10µF electrolytic & 0.1µF ceramic capacitors across output.
2. Line regulation is measured from 100Vac to 240Vac at full load.
3. Load regulation is measured from 10-100% of full load.