Powersolve PPS180 Series User Manual
Ac-dc converters, Power derating curve
Powersolve Electronics Ltd. Units 8A, Arnhem Road, Newbury, RG14 5RU. England
Tel:01635 521858 Fax: 01635 523771 Email: [email protected]
www.powersolve.co.uk
AC-DC Converters
PPS180 Series
130/180 Watts
Single, Dual, Triple & Quad Outputs
Features
•
Universal AC input
•
Built-in EMI filter
•
Optional Power Good Signal
•
Optional 12V, 24V or 48V DC input
(Consult sales office for details)
•
Optional Cover
INPUT
Input range
90~264 VAC, universal, auto select
Frequency
47~63Hz
Inrush current
40A typical, Cold start @ 25°C, 115 VAC
Efficiency
65%~85% typical at full load
EMI filter
FCC Class B conducted, CISPR 22 Class B conducted, EN55022 class B Conducted
Line regulation
±0.5% typical
OUTPUT
Maximum power
180W with 30 CFM forced air. 130 Watts convection cooled. See power derating curve
Peak power
210 watts
Output adjust
±10% output 1
Hold-up time
10ms typical at full load and 115 VAC nominal line
Overload protection
Short circuit protection
Overvoltage protection
Main output 20% to 40% above nominal output
Ripple/Noise
±1% Max. @ full load
Peak power
210 watts
Output adjust
±10% on output 1
ENVIRONMENTAL
Operating temperature
0 to 50°C ambient; derate each output at 2.5% per degree from 50°C to 70°C
Humidity
Operating; non-condensing, 5% to 95%
Vibration
10~55 Hz at 1G 3 minutes period, 30 minutes along X, Y and Z axis
Storage temperature
-40 to 85°C
Temperature coefficient
±0.05% per degree C
MTBF demonstrated
>100,000 hours at full load and 25°C ambient conditions
EMI & EMC
FCC part 15, Class B
CISPR 22 / EN55022, Class B
VCCI, Class 2
CE, EN 61000-3-2 (Class A) and –3; EN 61000-4-2, -3,-4.-5,-6 and -11
Safety approval
UL, cUL, TUV EN60950
Electrical Specification
180W
130W
80W
30W
90W
65W
Power Derating Curve
30 CFM Forced Air Cooling
010
20
30
40
50 60
70
Natural
Convection
Cooling
Output
Power
(Watts)
Ambient Temperature (°C)
Derate by 25% with