beautypg.com

Sm1500-series, Sm1500 series, Dc power supplies – Powersolve Short Form Catalogue User Manual

Page 6

background image

For full

specifications

and order information please visit

www.deltapowersupplies.com

DELTA ELEKTRONIKA

DC POWER SUPPLIES

DELTA ELEKTRONIKA

DC POWER SUPPLIES

8

9

For full

specifications

and order information please visit

www.deltapowersupplies.com

SM1500

Series

1500 W dC PoWer SUPPlieS

Features

Designed for long life at full power

Excellent dynamic response to load changes

Protected against all overload
and short circuit conditions

EMC surpasses CE requirements:
low emission & high immunity

Low audible noise: fan is
temperature controlled

Units

Voltage range

Current range

SM 15 - 100

0 -15 V

0 - 100 A

SM 35 - 45

0 - 35 V

0 - 45 A

SM 52 - 30

0 - 52 V

0 - 30 A

SM 52 - AR - 60
Autoranging output

0 - 26 V
0 - 52 V

0 - 60 A
0 - 30 A

SM 70 - 22

0 - 70 V

0 - 22 A

SM 120 - 13

0 - 120 V

0 - 13 A

SM 300 - 5

0 - 300 V

0 - 5 A

SM 400 - AR - 8
Autoranging output

0 - 200 V
0 - 400 V

0 - 8 A
0 - 4 A

Specifications

Single phase input

: 90-265 V AC (48-62 Hz)

Active Power Factor Correction (PFC) : 0.99 (at 100 % load)

Efficiency

: up to 91% (at full load)

Output ripple and spikes

: from 1.8 mV

rms

/ 8 mV

pp

Regulation

: from 0.5 mV (0-100% load step)

Recovery time

: from 100 µs (50-100% load step)

Programming speed

: from 3.4 ms (10-90%), optional from 0.2 ms

Analog programming accuracy

: from 0.2%

Output voltage and current stability : 6.10

-5

/ 9.10

-5

MTBF

: 500.000 hrs

Operating ambient temperature

: -20 to +50 °C

Functionalities

Master / Slave parallel and series operation
with voltage and current sharing

Stacking is allowed , space
between units is not required

19” rack mounting or for laboratory use
(feet included)

High power system configuration from
multiple units

Remote sensing

Interlock

Standards

Power supply standard EN 61204-3

Generic Emission

EN 61000-6-3 (EN 55022B)

Generic Immunity

EN 61000-6-2

Safety

EN 60950 / EN 61010

Insulation input / output 3750 V

rms

Enclosure

IP20

cTÜVus

Typical Applications

Solar Inverter testing, PV-simulation

Semiconductor burn-in & processing

Car test systems

ATE in industrial production lines

Lasers

Controlled battery (dis)charging

Component device testing

Driving PWM-controlled DC-motors

Accurate current sources

Aerospace and military equipment

Width = 19”
Height = 2 U

Weight = 9,9 kg

Dimensions and Weight

SM1500

Series

aPPliCationS & oPtionS

Available Options

Increased
Output Power

The conservatively rated
unit allows to deliver
extra output power with
the same reliability.

At some derating, either the maximum
output voltage or the maximum output
current can be increased by about 10%.

Increased Power Output

High Speed
Programming

A 10 to 20 times
higher programming
speed (down to 0.2 ms
rise time at full load)

and lower output capacitance.
Excellent for laser applications, test systems
or as current source with low parallel
capacitance as used in plasma chambers.

High Speed Programming

0,4ms

Two-Quadrant
Output: Power Sink

Two quadrant operation
maintains the output
voltage constant regardless
the output power is

positive or negative. Ideal for PWM-speed
controlled DC-motors and ATE systems.

Two-Quadrant Output:

Power Sink

Software Control
and Interfaces

Factory installed
programming interfaces:

Ethernet controller (incl. sequencer)

PROFIBUS controller

CANBUS controller

RS232 controller

IEEE488 controller

ISO AMP CARD – isolated analog

Software Control

& Interfaces

Sequencer

Arbitrary Waveform
generator or stand-
alone automation.
The sequencer is integrated
in the Ethernet controller.

Sequencer

Digital Voltage and
Current Setting

Reliable, longlife digital
encoders can be
implemented at the front
panel.

Includes total front panel lock (also for
CV / CC-knobs) and a coarse or fine pitch
adjustment depending on the turning speed.

Digital Encoders

Secured Voltage and
Current Setting

For maximum security, the
CV / CC settings can be
adjusted with a screwdriver
only and are protected

with a plastic cap from accidental adjusting.

Secured Voltage and

Current Setting

High Voltage Isolation

A higher output isolation
allows series operation
up to 1000 V.

High Voltage Isolation

More information about this:

Page

22

Details about interfaces:

Page

22-24