beautypg.com

Analog-series, Analog series, Dc power supplies – Powersolve Short Form Catalogue User Manual

Page 14

background image

DELTA ELEKTRONIKA

DC POWER SUPPLIES

24

For full

specifications

and order information please visit

www.deltapowersupplies.com

analog

Series

analog interFaCeS

Specifications

Programming and monitoring offset : +/- 60 µV typical

Full scale error

: 0.1% calibrated

Non-linearity

: 0.01% typical, TC = - 65ppm/°C

Common mode rejection

: 80 dB @ 50 Hz

Features

Selectable 0-5 V and 0-10 V signal levels

Isolated programming and monitoring of U, I and status signals

Prevents problems with earth loops and CM-voltages

Factory installed or external module

Reinforced safety insulation 1000 VDC*

* External module has Basic insulation only

Unit

ISO AMP

Isolated Analog Programming

Specifications

Programming and monitoring offset : +/- 60 µV typical

Full scale error

: 0.1% calibrated

Non-linearity

: 0.01% typical, TC = - 65ppm/°C

Common mode rejection

: 80 dB @ 50 Hz

Features

Connecting SM3000 and ES-series in M/S series mode

Equal voltage sharing in series operation

Series operation possible up to 600 V

Unit

M / S - ADAPTER

Master / Slave Series Adapter

Specifications

Undervoltage range : 18-48 V

Overvoltage range : 24-64 V

Insulation between circuits : 500 V DC

Alarm contact : 100 mA / 30 V, Normally Closed

Features

Large adjustment for use on both 24 V and 48 V

Two isolated comparator circuits with alarm contact and LED indication

Monitors output voltage of 2 power supplies

Unit

AL 24-48

Under and Over Voltage Alarm