Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England

Tel: 01635 521858 Fax: 01635 523771 Email: [email protected]

www.powersolve.co.uk

Uninterruptible Power Supplies

Models and Ratings

MODEL

OUTPUT POWER

OUTPUT CURRENT

AUTONOMY

VA

Watts

(at 230VAC)

(full load)

Xi1000

1000VA

700W

4.3A

12 Minutes

Xi1500

1500VA

1050W

6.5A

9 Minutes

Xi2500

2500VA

1750W

10.8A

9 Minutes

Xi3000

3000VA

2100W

13.0A

7 Minutes

Xi4000

4000VA

2800W

17.3A

12 Minutes

Xi5000

5000VA

3500W

21.7A

9 Minutes

Xi6000

6000VA

4200W

26.0A

7 Minutes

MODEL

OUTPUT POWER

OUTPUT CURRENT

AUTONOMY

VA

Watts

(at 115VAC)

(full load)

Xi1500L CE

1500VA

1050W

13.0A

5 Minutes

Xi3000L 120

3000VA

2100W

26.0A

5 Minutes

Accessory Products

Xi 232

RS232 Option Card giving second RS232 function

Xi BM 110C

Battery modules for Xi series UPS - fitted with 2 x Xi BP with additional 110V input charger for extended run times

Xi BP

Battery pack - contains 4 x 7Ahr VRLA 5 year design life batteries

Xi BMC

Battery module for Xi series UPS - populated with 2 x Xi BP, with additional charger for extended run times

Xi BB1K5

(1)

Make before break dual input multi format bypass module for Xi1000 & Xi1500.
Provides safety interlock when used with Xi V.

Xi BB3K

(1)

Make before break dual input multi format bypass module for Xi2500 & Xi3000.
Provides safety interlock when used with Xi V.

Xi BB6K

(1)

Make before break dual input multi format bypass module for Xi4000 & Xi6000.
Provides safety interlock when used with Xi V.

Xi R

Telescopic rack guides for UPS and battery modules

Xi S

SNMP Network Adaptor Option Card replaces USB port, allowing the UPS to be addressed directly on the LAN

Xi V

AS400 Volt Free Contact Option Card replaces USB comms port with a 15 way D-type connector
Providing Utility Fail, Battery Low, Bypass & UPS Alarm Contacts

(1). Unit can be used without Xi V. However, there is no automatic protection against bypass operation while the unit is on inverter. Units must operate
with common neutral. Contact sales office for details.

Option Order Codes

Power (VA)

Options

(1)

E.G. Xi1000RX

Xi Series, 1000VA

With telescopic rail guides and 10 year design life batteries fitted

Options (Examples)
Add suffix ‘R’ to Model Number - Adds rack guides to unit for 19” rack mounting
Add suffix ‘S’ to Model Number - Adds internal SNMP to UPS (in place of USB port)
Add suffix ‘V’ to Model Number - Adds AS400 VFC to UPS for Utility Fail, Bypass, Battery Low and UPS Fault (in place of USB port)
Add suffix ‘X’ to Model Number - Replaces 5 year design life batteries with 10 year

(1) Options should be listed in alphabetical order