Remote On/Off

Enable a 10…30Vdc 20mA voltage
signal to (Rmt/Rm) to shutdown the
HPW, the yellow LED lights and 0V
is distributed to the outputs.
If the shutdown is short circuited or
<500mV are applied to (Rmt/Rm),
the HPW „tickers“, the yellow LED
flashes and 5V is distributed to the
outputs
Disable the remote voltage to restart
the PSU

DC o.k. Message

Low Voltage:
If adjusted Vout drops 10% the red LED lights
and the DC-OK-Relay (Re) drops (control
message). The green DC-OK LED is off.
Overload: If 0.9xVout applies to the outputs, the
red LED lights and the DC-OK-Relay (Re)
drops (control message). The green DC-OK
LED is off.
Vout o.k. = relay closed
Vout fail = relay open

Series Connection

Redundant Connection

Inrush Current Limitation (Block Diagram)


To increase the output power, equal
HPW devices can be used series
connected. Observe to safety
directives when the output voltage
achieves 60Vdc in sum.


To increase system availability up to
fife HPW can be used in parallel
operation mode. Please make sure
that wiring length from all units to
the load is equal. Full redundant
operation modes require external
diodes.
We suggest to use our RED00202
DIN-Rail N+1 redundant module für
professional redundancy.

While connecting the HPW to the
AC wire network its inrush current is
limted to <7A (typ.). The start
capacitors are loaded after 80ms
and the HPW actuates. After
passing softstart (active PFC) the
power supply is ready for operation
after a total of t=130ms.
Characteristics Vi=230Vac:
Peak Inrush Current = <7A (typ.)
Peak Limiting Duration = 80ms

Power Boost and Temperature Behaviour


The HPW02401 operates in accordance to the V/C-characteristic line (see
graph I/Boost on page 2). It has a determinate power reserve (boost): With
ambient temperatures

40°C the power boost is continuously available

while with higher ambient temperatures it is available for a few minutes.
When a DC short circuit or an overload occurs to the HPW02401, it is
limited to I/Boost (see graph) but it is not shot down. The DC-voltage is
lowered until the error is rectified. The V/C-line and the powerboost applies
operation of critical loads, like DC-DC-converters, capacitive loads, drives
and batteries, trustworthy.

Output voltage/current ratio to ambient (U/I to °C)

Uout

40°C/Iout 60°C/Iout Uout

40°C/Iout 60°C/Iout

9Vdc

19,0A

15,0A

32Vdc

8,7A

7,5A

12Vdc

19,0A

15,0A

34Vdc

8,7A

7,1A

15Vdc

17,1A

13,5A

36Vdc

8,7A

6,7A

18Vdc

15,6A

12,0A

40Vdc

7,8A

6,0A

20Vdc

13,0A

11,3A

46Vdc

6,8A

5,2A

22Vdc

13,0A

10,7A

53Vdc

5,9A

4,5A

24Vdc

13,0A

10,0A

60Vdc

5,2A

4,0A

26Vdc

12,0A

9,2A

65Vdc

4,8A

3,7A

28Vdc

11,2A

8,6A

72Vdc

4,3A

3,3A

30Vdc

10,4A

8,0A

86Vdc

3,6A

2,8A

Test

Time A

B

C

D

Type test and factory tests are
conducted by the manufacturer.
Do not repeat the test in field.
Field test rules:

Type Test

60s

2500Vac 3000Vac 500Vdc 500Vdc

Factory Test 5s

2000Vac 2000Vac 500Vdc 500Vdc

Field Test

2s

2000Vac 2000Vac 500Vdc 500Vdc

a)

Use approriate test equipment which apply the voltage with a slow ramp

b)

Connect L1 and N together, as well as all output poles

c)

Use only AC test-voltages with 50/60Hz. The output voltages is floating and has
no ohmic reference to ground.

d)

If testing output voltages are

60Vdc remain to security directives.

Use only isolated screw drivers to adjust output voltages.

Function Table and Messages

Indicators

DC-ok
LED green

Overload
LED red

Shutdown LED
yellow

DC-ok Relay

Normal operation

On

Off

Off

Closed

Powerboost

On

Off

Off

Closed

Overload (0.9xVout)

Off

On

Off

Open

Shutdown with open contact On

Off

Off

Closed

Shutdown with 10..30Vdc

Off

Off

On

Open

Shutdown with <500mVdc

Off

Pulse

Pulse

Open

Temperature shutdown

Off

Off

Off

Open

Input voltage low or fail

Off

Off

Off

Open