beautypg.com

Powersolve HPW02401 Series User Manual

Page 2

background image

Powersolve Electronics Ltd., Unit 8A Arnhem Road, Newbury RG14 5RU, United Kingdom
Tel 0044 (0)1635 521858 Fax 0044 (0)1635 523771

www.powersolve.co.uk

[email protected]

p.2/4 03.12B

(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)

AC Input

85...264Vac , 47...63Hz , 90…350Vdc

AC Input Rating

100...240Vac , 115Vac <2.6A 230Vac <1.3A

DC Voltage Adjust

9...18Vdc(12V)

18..30Vdc(24V) 30...43Vdc(36V) 43...53Vdc(48V) 53...72Vdc(60V) 68...86Vdc(72V)

Over Voltage
Protection

21Vdc

35Vdc

50Vdc

60Vdc

84Vdc

97Vdc

Rated Current 60°C 15.0A (12Vdc)

10.0A (24Vdc)

6.7A (36Vdc)

5.0A (48Vdc)

4.0A (60Vdc)

3.3A (72Vdc)

Rated Current 40°C 19.0A (12Vdc)

13.0A (24Vdc)

8.7A (36Vdc)

6.5A (48Vdc)

5.2A (60Vdc)

4.3A (72Vdc)

Boost 60s/60°C

18.0A (12Vdc)

12.0A (24Vdc)

8.0A (36Vdc)

6.0A (48Vdc)

4.8A (60Vdc)

4.0A (72Vdc)

Ripple

mVpp/230Vac

30 (20MHz)

30 (20MHz)

60 (20MHz)

50 (20MHz)

50 (20MHz)

60mV

Load regulation 0-
100%

±0.5%

±0.2%

±0.2%

±0.2%

±0.2%

±0.2%

Tolerance Ua adjusted

± 0.5%

Transient Time

<1ms (10-100% , 100-10%)

Minimum Load

0 A

Efficiency

91.5% typical

Load Protection

1,2x I

rated

, auto recovery

Short Circuit Protection

Yes

Temperature Controlled

Yes (see right graph)

Hold Up Time

> 40ms (100...230Vac input)

Inrush Current

< 7A (230Vac), active limiter

Softstart

50ms typical











Temperature Control:

If the ambient temperature (ta)

40°C the HPW provides I/Boost

continuously and if ta

60°C Irated is provided continuously. If ta >60°C

derating continuously lowers Vout 2,5%/Kelvin. If ta >70°C (or thermal
overload occures) the HPW shuts down. It auto-recovers when the
device cools down to approved operation conditions.

Cooling

Natural convection

Ambient Temperature

- 25°C…+70°C

Storage Temperature

- 40°C…+85°C

EMI

EN55022 class B / EN61000-3-2

EMS

EN61000-6-2,3 active PFC

Safety

cUL60950 , (IEC)EN60950-1

Safety class 1(A)

VDE0805, VDE0100

Air & Surface Leakage Paths

> 8mm

Input/Output

Galvanic insulated

DC Fail Relay (galv. insulated)

48Vdc/500mA ,

30Vac/500mA

Relative Humidity

95% (25°C) non-condensing

Pollution Degree

2 (EN50178)

Climatic Class

3k3 (EN60721)

MTBF (IEC61709)

500000h

Dimensions (HxWxD)

130x75x115mm

Weight

1200g

Connectors (AC & DC)

(see page 4)

AWG20...AWG6
IEC60664-1, IEC61984


Specification:
The HPW02401 DIN Rail power supply series is designed for worldwide electronics applications like machine building, railway,
military and factory automation. Its regulated DC output with ripple/noise lower than 30mVpp and its high efficiency of 91.5%
makes the HPW robust, economical and reliable. Camtec power supplies are tradionally made with high end low ESR
electrolytic output capacitors with withstanding +125°C temperature. Our capacities are rather designed over for longer
lifetime and longer hold up times. The power boost of the HPW starts DC-loads and DC-motors reliable. The built in function
diagnostics detects malefunctions. The galvanic insulated DC fail relay and remote on/off provides full control over the power
supply unit. The HPW is short circuit and zero load stability protected. It is protected against high transient and provides very
good interference resistance. Equal types of the HPW02401 can be operated in parallel or in series connection. We use IP20
stabile aluminium hausings with vantilation slots in accordance to the demanding VDE norms.
The design meets EN (IEC)60950-1 and low voltage directive EN55022 Class B.

Block Diagram

1)

Transient suppressor (VDR)

2)

AC fuse

3)

Electronic Inrush Current Limiter

4)

Load Capacitor C

5)

Rectifier & Active PFC

P Potentiometer


Complex sane filter technology using 2 varistors, noise
suppression chokes and X1 capacitors, apply major transient
resistance to the input filter. The synchron rectifier increases the
efficiency of the APW crucial. Compared to diode rectifying the
power dissipation drops to a minimum. The emission is much
lower to result in a longer lifetime of the APW power supply.

Overload: If 0.9xVout applies to the outputs, the red LED lights and
the DC-OK-Relay (Re) drops (control message). The green DC-OK
LED is off.

For further
derating
information
see table
page 3