beautypg.com

Ac-dc converters, Mp xxx, Example – Powersolve MP Series User Manual

Page 5: Ordering information

background image

Powersolve Electronics Ltd. Units 8A, Arnhem Road, Newbury, RG14 5RU. England

Tel:01635 521858 Fax: 01635 523771 Email: [email protected]

www.powersolve.co.uk

AC-DC Converters

Example

MP

XXX

Slot

#1

2 or 3 digit code

See previous page.

Use

”_” for Standard Remote Sense

Use

”/” After and module using Remote

Sense with or-ing diode (redundancy)

Use Only for

Modified Standard

Slot

#2

Slot

#3

Slot

#4

Slot

#5

Slot

#6

(MP1 Only)

(MP8 & MP1 Only)

Slot

#7

Option Code
0

= no options

1

= rear air exhaust

3

= global enable

5

= option package (options 1 & 3)

M

= low leakage

N

= low leakage plus option 1

P

= low leakage plus option 3

R

= low leakage plus option 5

INPUT

Case Size (inches)

Slots

85-264 VAC

180-264 VAC

4 = 2.5 x 5 x 10

5 available slots

400 W max.

600 W max.

6 = 2.5 x 5 x 11

5 available slots

600 W max.

800 W max.

8 = 2.5 x 7 x 10

6 available slots

800 W max.

1000 W max.

1 = 2.5 x 8 x 11

7 available slots

1000 W max.*

1200 W max.

*1200 W available at high line operation

Note:
1. Omit digits that do not apply.
2. Specify modules from lowest number of outputs to highest. (Single/Dual/Triple)
3. If number of outputs are equal, specify modules from highest to lowest power increments. If power increments are equal, specify in

descending alphabetical order (1A, B, C . . .).

4. Always start with Slot 1.
5. All MP model configurations created using this selection guide are standard MP products with standard availability and lead times.
6. Optional VME/DCOK module must always be located in the last slot. Module designator is “VME”.

Ordering Information

2.5” x 7” x 10”

(6 slots

available)

Slot 3

Output 2:

12V @ 17 A

Slots 1 & 2

Output 1:

5.2V @ 60 A

Slot 4

Output 3: 12V @ 10

Output 4: 5V @ 10A

Slot 5

Output 5: 12V @ 1 A
Output 6: 12V @ 1 A

Output 7: 5V @ 2 A

Factory assisted
code for
modifications

VME
HUP

0M

X X X

VME Card

Hold-up Module

No Paralleling

Low Leakage

Parallel Code:

Standard Parallel Codes*

7 6

5

4

3

2

1

0

= no parallel

o o

o o

o

o

o

1

= 1 & 2

o o

o o

o

o

o

2

= 2 & 3

o o

o o

o

o

o

3

= 3 & 4

o o

o o

o

o

o

4

= 4 & 5

o o

o o

o

o

o

5

= 3 & 4 & 5

o o

o o

o

o

o

6

= 5 & 6

o o

o o

o

o

o

7

= 4. 5 & 6

o o

o o

o

o

o

8

= 6 & 7

o o

o o

o

o

o

9

= 3 & 4, 6 & 7

o o

o o

o

o

o

* For custom parallel configurations contact
Astec Power Technical Support.

MP4 & MP6

available slots

MP8

available slots

MP1

available slots

Slot 7

Slot 6

Slot 5

Slot 4

Slot 3

Slot 2

Slot 1

Slot 6

Slot 5

Slot 4

Slot 3

Slot 2

Slot 1

Slot 5

Slot 4

Slot 3

Slot 2

Slot 1

M

P

8

2

F

1

L

4

L

E

L

L