Ac-dc converters, Mp xxx, Example – Powersolve MP Series User Manual
Page 5: Ordering information

Powersolve Electronics Ltd. Units 8A, Arnhem Road, Newbury, RG14 5RU. England
Tel:01635 521858 Fax: 01635 523771 Email: [email protected]
www.powersolve.co.uk
AC-DC Converters
Example
MP
XXX
Slot
#1
2 or 3 digit code
See previous page.
Use
”_” for Standard Remote Sense
Use
”/” After and module using Remote
Sense with or-ing diode (redundancy)
Use Only for
Modified Standard
Slot
#2
Slot
#3
Slot
#4
Slot
#5
Slot
#6
(MP1 Only)
(MP8 & MP1 Only)
Slot
#7
Option Code
0
= no options
1
= rear air exhaust
3
= global enable
5
= option package (options 1 & 3)
M
= low leakage
N
= low leakage plus option 1
P
= low leakage plus option 3
R
= low leakage plus option 5
INPUT
Case Size (inches)
Slots
85-264 VAC
180-264 VAC
4 = 2.5 x 5 x 10
5 available slots
400 W max.
600 W max.
6 = 2.5 x 5 x 11
5 available slots
600 W max.
800 W max.
8 = 2.5 x 7 x 10
6 available slots
800 W max.
1000 W max.
1 = 2.5 x 8 x 11
7 available slots
1000 W max.*
1200 W max.
*1200 W available at high line operation
Note:
1. Omit digits that do not apply.
2. Specify modules from lowest number of outputs to highest. (Single/Dual/Triple)
3. If number of outputs are equal, specify modules from highest to lowest power increments. If power increments are equal, specify in
descending alphabetical order (1A, B, C . . .).
4. Always start with Slot 1.
5. All MP model configurations created using this selection guide are standard MP products with standard availability and lead times.
6. Optional VME/DCOK module must always be located in the last slot. Module designator is “VME”.
Ordering Information
2.5” x 7” x 10”
(6 slots
available)
Slot 3
Output 2:
12V @ 17 A
Slots 1 & 2
Output 1:
5.2V @ 60 A
Slot 4
Output 3: 12V @ 10
Output 4: 5V @ 10A
Slot 5
Output 5: 12V @ 1 A
Output 6: 12V @ 1 A
Output 7: 5V @ 2 A
Factory assisted
code for
modifications
VME
HUP
0M
X X X
VME Card
Hold-up Module
No Paralleling
Low Leakage
Parallel Code:
Standard Parallel Codes*
7 6
5
4
3
2
1
0
= no parallel
o o
o o
o
o
o
1
= 1 & 2
o o
o o
o
o
o
2
= 2 & 3
o o
o o
o
o
o
3
= 3 & 4
o o
o o
o
o
o
4
= 4 & 5
o o
o o
o
o
o
5
= 3 & 4 & 5
o o
o o
o
o
o
6
= 5 & 6
o o
o o
o
o
o
7
= 4. 5 & 6
o o
o o
o
o
o
8
= 6 & 7
o o
o o
o
o
o
9
= 3 & 4, 6 & 7
o o
o o
o
o
o
* For custom parallel configurations contact
Astec Power Technical Support.
MP4 & MP6
available slots
MP8
available slots
MP1
available slots
Slot 7
Slot 6
Slot 5
Slot 4
Slot 3
Slot 2
Slot 1
Slot 6
Slot 5
Slot 4
Slot 3
Slot 2
Slot 1
Slot 5
Slot 4
Slot 3
Slot 2
Slot 1
M
P
8
2
F
1
L
4
L
E
L
L
E