beautypg.com

Powersolve HSEUIreg04801 Series User Manual

Page 8

background image


Powersolve Electronics Ltd., Unit 8A Arnhem Road, Newbury RG14 5RU, United Kingdom
Tel 0044 (0)1635 521858 Fax 0044 (0)1635 523771

www.powersolve.co.uk

[email protected]

p.8/9 05.12D

(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)

Coating Option

We offer the USEUIreg-series with optional coating. It is to be used in e.g. dusty, dirty, high humidity, or in awaiting quick temperature
changes. Short circuit and corrosion at print board lines and at solder points can be prevented. The coat itself is a transparent acrylic
resin. It is procured with a robotics varnishing machine.
Peters SL 1306 N-FLZ (transparent) IEC60216-1 2001, IPC-CC-830B, UL listed as permanent coating FileNo.: E80315 , UL94V-0

Ordering Information: ad extension C to the type number: HSEUIreg04801.180T

C

Test

Time A

B

C

¹)

D

Type test and factory tests are
conducted by the manufacturer.
Do not repeat the test in field.
Field test rules:

Type Test

60s

2500Vac 3000Vac 500Vdc 500Vdc

Factory Test 5s

2000Vac 2000Vac 500Vdc 500Vdc

Field Test

2s

2000Vac 2000Vac 500Vdc 500Vdc

¹)

90Vdc = 1500Vac

a)

Use approriate test equipment which apply the voltage with a slow ramp

b)

Connect L1 and N together, as well as all output poles

c)

Use only AC test-voltages with 50/60Hz. The output voltages is floating and has
no ohmic reference to ground.

d)

If testing output voltages are

60Vdc remain to security directives.

Use only isolated screw drivers to adjust output voltages.

Terminal Connects:


AC Main Input
GND common
N - wire
L - wire



DC Mains Outputs

DC + voltage
DC + voltage
DC - voltage
DC - voltage



Inputs/Outputs
Ureg

= programmable voltage input

Ureg

= programmable current input

Umon

= voltage monitor output

Imon

= current monitor output

SD

= shut down input

Uref

= reference voltage (poti connection)



Standard Feature Connects
C= external power sink
B= sense connections (S+/-) &
operation failure relay (output)

Mechanics & Installation of the HSEUIreg
Stable metal/aluminium housing IP20. To allow adequate convection, a free air space of 50mm (top/bottom) and 5mm (sidewalls) is
required; for active devices 15mm space from the sidewalls. For free air convection it is necessary to install the HSEUIreg horizontal. You
can use the DIN-Rail installation (equiped standard) with our patented 35mm DIN-Rail bracket according to EN60275. It is easy to
mount/dismount while snaping it onto the 35mm DIN-Rail - any tools necessary. A wallmount backplate (option) is availble, too






























Backplate Option