Powersolve HSEUIreg04801 Series User Manual
Page 6
Powersolve Electronics Ltd., Unit 8A Arnhem Road, Newbury RG14 5RU, United Kingdom
Tel 0044 (0)1635 521858 Fax 0044 (0)1635 523771
www.powersolve.co.uk
p.6/9 05.12D
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
Series Connection (fig.1)
Parallel Connection (fig.2)
Over Voltage Protection (3a) Temperature Derating (fig.3)
Vout
OVP
Iout
-25°C...+60°C
Iout
+70°C
0...18Vdc
22Vdc
40.0A
30.0A
0...30Vdc
35Vdc
24.0A
18.0A
0...50Vdc
59Vdc
15.0A
11.3A
0...90Vdc
105Vdc
8.0A
6.0A
0...130Vdc
150Vdc
5.5A
4.1A
0...180Vdc
210Vdc
4.0A
3.0A
0...240Vdc
280Vdc
3.0A
2.3A
Power Good (fig.4)
Function LED-Bar
ADTW201 Isolating Transformer (fig5)
Series Connection (fig.1)
To increase output voltage equal HSEUIreg can be
connected in series. The control I/O should be galvanic
insulated in the series mode. If not the minus main output
is connected to the control I/O. Use our external option
Isolating Transformer ADTW201 being validated with the
HSEUIreg. Be aware of safety norms if your target output
voltage exceeds safety voltage.
Parallel Connection (fig.2)
To increase the output power up to 5 HSEUIreg can be
parallel connected. Advise using busbars to connect
HSEUIreg in parallel. Always use identical length and
identical cross sections to the busbar.
ADTW201 Isolating Transformer (option) (fig.5)
The isolating transformer is used to galvanic isolate
impressed current. The device is self powered. The input
to output ratio is 1:1. For further information seek advice
from page 10.
Derating & Over Temperature (fig.3)
If the ambient temperature exceeds trigger pint >70°C the
HSEUIreg shuts down (metering point 10mm from
outside device). After being recovered from over
temperature the device restarts automatically to normal
operation.
OVP Over Voltage protection (3a)
The HSEUIreg features over voltage protection.
Exceeding OVP results in a locked shutdown mode.
Resuming the failure causes automatic restart into normal
operation.
Power Good Signal (fig.4)
Galvanic insulated open with failure, closed at normal
operation.
CV
GRN
Constant voltage
CC
YEL
Constant current
SD
YEL
shutdown
OT
RED
Over temperature
30Vac 1000mA
30Vdc 500mA
60Vdc 300mA
Technical Information ADTW201 external DC-Repeater
Input (Ie)
0…20mA, 4…20mA (max. 50mA)
Voltage drop (Uw)
Uw>1.5V (Ie=20mA)
Max. apparent ohmic resistance (Ra)
500R @ Ie=20mA
Input Impedance (R)
R=Ra+Uw/IE
Barrier Frequency (Fa)
Fa=5kHz (-3dB) with Ra=500R @ Ie=20mA
Output
1:1
Ripple / Noise
>0,5% with 20mA and Ra=500R
Linear Failure
>0,03% / 100R
Transient oscillation current
35uA
Latency
150us 0..20mA, Ra=500R, 10…90%
Isolation Voltage Input/output
500V
Operation Temperature
0…50°C
Temperature Drift
Approx. 15ppm/K
Weight
21g
Ordering Information
Part No: 304.1090.001CA