5 standard connections for pulse sensors, Standard connection with sensor bearing, Standard connection with encoder 24 ppr – R&M Materials Handling VARIABLE SPEED CONTROLS ControlMaster Plus Service Manual User Manual
Page 82: Standard connection with encoder 600 ppr or more

R&M Materials Handling, Inc.
4501 Gateway Boulevard
Springfield, Ohio 45502
P.: (937) 328-5100
FAX: (937) 325-5319
82/83
R&M Materials Handling, Inc. reserves the right to alter or amend the above information without notice.
4.5 Standard connections for pulse sensors.
Standard connection with sensor bearing.
:55
+24V
:51
EA+
:54
EB-
IN
V
E
R
T
E
R
black
+V
0V
red
:56
0V
:53
EB+
:52
EA-
G
white
A+
D2L
X1
KAE 234
6
1
2
3
4
7
blue
B+
BROWN
GREEN
WHITE
Standard connection with sensor bearing. Two
channels connected for Synchro.
:55
+24V
:51
EA+
:54
EB-
IN
V
E
R
T
E
R
:56
0V
:53
EB+
:52
EA-
D2L
X1
black
+V
0V
red
G
white
A+
KAE 234
6
1
2
3
4
7
blue
B+
BROWN
GREEN
WHITE
KAE 234
6
1
2
3
4
7
YELLOW
Standard connection with encoder 24 ppr.
:55
+24V
:51
EA+
:54
EB-
IN
V
E
R
T
E
R
blue
+V
0V
red
:56
0V
:53
EB+
:52
EA-
G
yellow
A+
terminal box
D2L
X1
Standard connection with encoder 600 ppr or
more.
:55
+24V
:51
EA+
:54
EB-
IN
V
E
R
T
E
R
black
blue
+V
A-
0V
red
:56
0V
:53
EB+
:52
EA-
G
yellow
A+
green
B+
white
B-
terminal box
D2L
X1