6 i/o extension board (slot d), 7 system bus board (slot e, option), 15 control voltage transformer – R&M Materials Handling VARIABLE SPEED CONTROLS ControlMaster Plus Service Manual User Manual
Page 19
R&M Materials Handling, Inc.
4501 Gateway Boulevard
Springfield, Ohio 45502
P.: (937) 328-5100
FAX: (937) 325-5319
19/83
R&M Materials Handling, Inc. reserves the right to alter or amend the above information without notice.
28
ROC1
Relay output, 250V 8A, normal open
29
ROC1
Relay contact ROC1 closes when inverter is powered and no faults occurs
Relay contact ROC1 opens if the SSU has tripped in:
Overspeed
Speed difference
Zero speed
Relay test fault
Watch dog fault
LED
Blinking
Status
Red
1Hz
OK
Yellow
0.25Hz
OK
Yellow
4Hz
Board internal fault or communication fault with control unit
1.14.6 I/O Extension board (Slot D)
NXOPTB9 / I/O Extension board
ID: 52305691
YELLOW
1
2
3
4
5
6
7
8
Terminal
Signal name
Description
1
DID1
Not used
2
DID2
42-240Vac 50/60Hz
3
DID3
42-240Vac 50/60Hz
4
DID4
42-240Vac 50/60Hz
5
DID5
42-240Vac 50/60Hz
6
COM
Common for DID1-DID5
7
ROD1
Relay output, 250V 8A, normal open
For fan of braking resistor unit
8
ROD1
The threshold voltage for digital inputs DID1-DID5 is 35VAC.
LED
Blinking
Status
Yellow
0.25Hz
OK
Yellow
4Hz
Board internal fault or communication fault with control
unit
1.14.7 System bus board (Slot E, option)
NXOPTD1L System bus board
ID: 52354858
H1 H2 H3 H4
Terminal
Signal name
Description
H1
RX1
SystemBus optical input 1.
H2
RX2
SystemBus optical input 2.
H3
RX3
SystemBus optical output 1.
H4
RX4
SystemBus optical output 2.
Optical cables
Specification
ID:
Length
[m]
Bend radius
SYS-1M
52354911
1
> 35mm ( >1.3 inch)
SYS-2M
52354876
2
> 35mm ( >1.3 inch)
SYS-4M
52354912
4
> 35mm ( >1.3 inch)
1.15 Control voltage transformer
Power of control voltage transformer has to be n * 50VA + 50VA (min. 250VA), n = number of inverters. This power does
not have to be added to otherwise needed transformer power.