Section 4 - Configuring the Serial Server

Vlinx VESR4x4 Serial Server

Page 31 of 66

Manual Documentation Number: VESP211-5011m

www.bb-elec.com/

www.bb-europe.com/

You can also configure the serial server to receive from nodes on the network
using the same list of configuration options.

Figure 27.

UDP Configuration

Setting the serial server to use UDP

1. Select

UDP

protocol.

Options are provided for sending and receiving data to and from:

Nobody

Everyone on a specific UDP Port

Only specific IP addresses

Only a range of IP addresses

Additional configuration fields appear depending on the options chosen.

2. Select the required

Send

options:

a.

nobody

- sends to nobody

b.

everyone on a specific UDP port (send broadcast)

- sends to all UDP

ports on the network (specified later)

c.

only specific IP addresses (send unicast)

- sends to specific network

IP addresses (specified later)

d.

only a range of IP addresses (send unicast range)

- sends to all IP

addresses within a specified range (specified later)

3. Configure the