beautypg.com

B&B Electronics VESP211 Series - Manual User Manual

Page 29

background image

Section 4 - Configuring the Serial Server

Vlinx VESR4x4 Serial Server

Page 29 of 66

Manual Documentation Number: VESP211-5011m

www.bb-elec.com/

www.bb-europe.com/

TCP Configuration

TCP (Transmission Control Protocol)

provides reliable connection-oriented

network communication with error checking. In TCP mode the serial server can
be configured as a client or a server.

When you configure the serial server as a

TCP client

it initiates connections

with a server on the network. You must set up the IP address and port number
of the server that you want the client (serial server) to communicate with. You
also select whether you want the serial server to connect at power up or only
when it receives data from the device connected to its serial port.

When the serial server is configured as a

TCP server

it waits for connections

to be initiated by another network device. You must set up the TCP port
number that it will listen to for connections and set the maximum (up to eight)
number of simultaneous connections it will accept. You can filter the
connections it will accept based on specific IP addresses or ranges of IP
addresses that you specify.

Figure 25.

TCP Configuration

Setting the serial server to operate as a TCP Client

1. Select

TCP

protocol.

2.

Select

to initiate connections (client)

3. Type the IP address into the

I want to connect to IP address:

box

4. Type the TCP port number of the server into the

on TCP port number:

box.