TC Electronic UpCon User Manual
Page 29

Setting up GPI/O
English Manual 25
GPO 1 and GPO 2 parameters
Use the GPO 1 and GPO 2 parameters to spec-
ify which status information should be transmit-
ted to the GPO pins. Available settings are “Off”, 
“Sync LED”, “Alert LED” and “Signal LED”. If you 
select one of the three LED options, the selected 
GPO pin pair will communicate the status of the 
respective UpCon front panel LED.
Idle State 1 and Idle State 2 parameters
Use the Idle State 1 and Idle State 2 parameters 
to specify which state of the respective GPO re-
lay (1 or 2) should represent the inactive state of 
the assigned LED/status information. Available 
settings are “Open” and “Closed”.
GPO setup example
– To signal UpCon Synchronization Status on 
GPO relay 1 – see “Sync LED(s)” on page 
10 –, set the GPO 1 parameter to “Sync 
LED”.
– If you set Idle State 1 to “Open”, the GPO 1
relay…
– will be open as long as no synchronization
has been achieved and
– will close when synchronization has been
achieved.