Example boost – Turbosmart BOOST CONTROLLERS – ELECTRONIC - e-Boost2 (2005-current) – Complete User Manual User Manual
Page 21

www.TURBOSMARTONLINE.com
21
SSA (Sequential switching function A): Allows you to sequentially switch between different boost settings. This switch logic could be
applied in a situation where you want to have a different boost level in each gear.
Earthing the green wire with a switch will scroll up a single set point.
Earthing the green wire again will switch up another single set point.
The maximum number of set points that can be switch up to is determined by nSP in the setup menu.
Once the maximum set point is reached through switching further switching not increase the set point any higher.
Earthing orange wire with a switch will reset and return to SP1.
SSB (Sequential switching function B): Sequential Switching Function B allows you to sequentially switch up and down between
different boost settings using external switches. This switch logic could be applied in a situation where you want to have a different
boost levels in each gear.
Earthing the green wire with a switch will switch up a single set point.
Earthing the green wire again will switch up another single set point.
The maximum number of set points that can be switch up to is determined by nSP in the setup menu.
Once the maximum set point is reached through switching (note: will only switch up to SP6).
Earthing orange with a switch will wire switch down a single set point.
Earthing the orange wire again will down another set point. (note: will only switch down to SP1).
Boost Curve
SP1
SP2
SP3
SP4
Ground Orange
Wire- Reset to SP1
Ground Green W ire
- trigger up SP
BOOST
SP5
SP6
TIME
Example Boost
SP1
Ground Green
Wire- trigger up SP
Ground Orange
Wire- trigger down
SP
SP2
SP3
SP4
SP5
BOOST
SP4
SP5
SP6
SP2
SP1
SP3
TIME