42
PNEG-1095 FCDL 4.00" Corrugation Externally Stiffened Grain Bin
FCDL Stiffener and Sidewall Gauges
Refer to
for stiffener lengths and color codes and
for sidewall color codes.
15' Diameter
18' Diameter
*NOTE: Base stiffener weldments are a minimum of 14 gauge.
15' Diameter FCDL up to 9 Rings
Bins with
Odd No.
of Rings
Stiffener
Gauges
Sidewall
Gauges
Stiffener
Gauges
Bins with
Even No.
of Gauges
1
16T
20
16T
1
2
*16
20
2
3
20
16
3
4
*16
20
4
5
20
14
5
6
12
20
6
7
20
12
7
8
12
18
8
9
18
15' Diameter FCDL 10 to 12 Rings
Bins with Odd
No. of Rings
Stiffener
Gauges
Sidewall
Gauges
Stiffener
Gauges
Bins with Even
No. of Gauges
1
16T
20
16T
1
2
16
20
2
3
20
16
3
4
16
20
4
5
20
14
5
6
12
20
6
7
20
12
7
8
12
18
8
9
18
10
9
10
10
18
10
11
18
8
11
18
12
15' Diameter FCDL 13 Rings
Bins with Odd
No. of Rings
Stiffener
Gauges
Sidewall
Gauges
Stiffener
Gauges
Bins with Even
No. of Gauges
1
16T
20
16T
1
2
16
20
2
3
20
16
3
4
16
20
4
5
20
14
5
6
12
20
6
7
20
12
7
8
12
18
8
9
18
10
9
10
10
18
10
11
18
8
11
12
8
18
12
13
17
18' Diameter FCDL up to 8 Rings
Bins with
Odd No.
of Rings
Stiffener
Gauges
Sidewall
Gauges
Stiffener
Gauges
Bins with
Even No.
of Gauges
1
16T
20
16T
1
2
*16
20
2
3
20
*16
3
4
*16
20
4
5
20
14
5
6
14
20
6
7
18
12
7
18
8
18' Diameter FCDL 9 Rings
Bins with
Odd No. of Rings
Stiffener Gauges
Sidewall Gauges
1
16T
20
2
16
20
3
20
4
16
20
5
20
6
12
20
7
20
8
10
18
9
18
18' Diameter FCDL 10 to 12 Rings
Bins with
Odd No. of
Rings
Stiffener
Gauges
Sidewall
Gauges
Stiffener
Gauges
Bins with
Even No. of
Gauges
1
16T
20
16T
1
2
16
20
2
3
20
16
3
4
16
20
4
5
20
14
5
6
12
20
6
7
20
10
7
8
12
18
8
9
18
8
9
10
10
18
10
11
17
8
11
17
12