beautypg.com

VEGA VEGAPULS 62 (≥ 2.0.0 - ≥ 4.0.0) Modbus and Levelmaster protocol Approval according to LPR radio standard User Manual

Page 76

background image

Sub Function Code

Name

0x00

Return Data Request

0x0B

Return Message Counter

With sub function codes 0x00 only one 16 bit value can be written.

FC16 Write Multiple Register

With this function code, several holding registers can be writen. Only registers can be written in an
enquiry which are immediately consecutive. If there are gaps (registers do not exist) between the
registers, then they cannot be written in a telegram.

Request:

Parameter

Length

Code/Data

Function Code

1 Byte

0x10

Start Address

2 Bytes

0x0000 to 0xFFFF

Register Value

2 Bytes

0x0001 to 0x007B

Byte Number

1 Byte

2*N

Register Value

N*2 Bytes

Data

Response:

Parameter

Length

Code/Data

Function Code

1 Byte

0x10

Sub Function Code

2 Bytes

0x0000 to 0xFFFF

Data

2 Bytes

0x01 to 0x7B

FC17 Report Slave ID

With this function code, the Slave ID can be queried.

Request:

Parameter

Length

Code/Data

Function Code

1 Byte

0x11

Response:

76

VEGAPULS

62 • Approval according to LPR radio standard

10 Supplement

41722

-EN

-120706