Gas phase

Temperature

Pressure

1

bar

(14.5 psig)

10

bar

(145 psig)

50

bar

(725 psig)

100

bar

(1450 psig)

200

bar

(2900 psig)

Air

20 °C/68 °F

0.00 %

0.22 %

1.2 %

2.4 %

4.9 %

200 °C/392 °F -0.01 %

0.13 %

0.74 %

1.5 %

3.0 %

400 °C/752 °F -0.02 %

0.08 %

0.52 %

1.1 %

2.1 %

Hydrogen

20 °C/68 °F

-0.01 %

0.10 %

0.61 %

1.2 %

2.5 %

200 °C/392 °F -0.02 %

0.05 %

0.37 %

0.76 %

1.6 %

400 °C/752 °F -0.02 %

0.03 %

0.25 %

0.53 %

1.1 %

Steam (satura-
ted steam)

100 °C/212 °F 0.26 %

-

-

-

-

180 °C/356 °F 0.17 %

2.1 %

-

-

-

264 °C/507 °F 0.12 %

1.44 %

9.2 %

-

-

366 °C/691 °F 0.07 %

1.01 %

5.7 %

13.2 %

76.0 %

Characteristics and performance data

Frequency

K-band (26 GHz technology)

Measuring cycle time

450 ms

Step response time

1)

3 s

Tracking speed of the measuring window
max.

1 m/min

Beam angle

2)

-

Horn antenna ø 75 mm (2.953 in)

10°

-

Horn antenna ø 95 mm (3.74 in)

Emitted HF power

3)

-

Average spectral transmission power
density

-34 dBm/MHz EIRP

-

Max. spectral transmission power den-
sity

+

6 dBm/50 MHz EIRP

-

Max. power density in a distance of 1 m

<

1 µW/cm²

1)

Time span after a sudden measuring distance change by max. 0.5 m in
liquid applications, max 2 m with bulk solids applications, until the output
signal has taken for the first time 90 % of the final value (IEC 61298-2).

2)

Outside the specified beam angle, the energy of the radar signal has a level
which is reduced by 50 % (-3 dB)

3)

EIRP: Equivalent Isotropic Radiated Power

64

VEGAPULS

62 • Approval according to LPR radio standard

10 Supplement