10 Measured value/Status files
RS232/Ethernet connection • VEGAMET 391/624/625, VEGASCAN 693, PLICSRADIO C62
30325-EN-130701
File content
Description
001,"TAG-No. 1",98,75,%
DCS value 1: no., measurement loop-TAG,
value, unit
002,"TAG-No. 2"98,65,%
DCS value 2: no., measurement loop-TAG,
value, unit
003,"TAG-No. 3",0.10,%
DCS value 3: no., measurement loop-TAG,
value, unit
In the CSVfile (Character Separated Values) the values are sepa-
rated by a certain character. Often a comma is used as separator. As
separators, the signs "Comma" (default setting), "Semicolon" and
"Tabulator" can be set. The individual data sets are separated by a
line break character.
CSV files are particularly suitable for import into spread sheet pro-
grams, such as Microsoft Excel.
Example of the content of a "val.csv" file of a VEGAMET 625.
File content
Description
#System: VEGAMET 625
Instrument type
#Version: 1.91
Firmware version
#TAG: Device Name
Device-TAG
#SNR: 11162431
Instrument serial number
#Date: 27.10.04
Transmission date
#Time: 14:42:34
Transmission time
#Ontime: 02:58:51
Switch on period
#PLS;TAG;VALUE;UNIT
Heading measured values
001,"TAG-No. 1",98,73,%
DCS value 1: no., measurement loop-TAG,
value, unit
002,"TAG-No. 2"98,65,%
DCS value 2: no., measurement loop-TAG,
value, unit
003,"TAG-No. 3",0.10,%
DCS value 3: no., measurement loop-TAG,
value, unit
With an HTML file, the information is transmitted in HTML format.
These files can be opened and displayed with a web browser (e.g.
Microsoft Explorer).
Example of the presentation of a "val.htm" file of a VEGASCAN 693
with Microsoft Internet Explorer.
CSV file