beautypg.com

2 adjustment with medium – VEGA VEGAMET 614 User Manual

Page 20

background image

20

VEGAMET 614

Settings in the "Reduced menu“

6.2 Adjustment with medium

You can either carry out the adjustment

with

medium or

without

medium. Adjustment with

medium means that you carry out the adjust-
ment taking the actual level into account. To
carry out an adjustment with medium, it is
necessary to know the percentage value of
the actual vessel filling.

In this procedure, the percentage values
which correspond to the actual min. and max.
fillings are entered. It doesn't matter if you
enter first the min. value or the max. value. If
you know, for example, that your filling is
actually 80 %, you can enter in the menu
"max. adjustment" the value "80“. Later, when
your filling is, for example, 10 %, you enter in
the menu "min. adjustment" the value "10“.

The bigger the difference between the two
adjustment points, the more precise the
measurement over the whole measuring
curve. An adjustment at 0 % and 100 %
would be ideal. For practical reasons, it is not
always possible to completely empty or fill a
vessel. The distance between the two adjust-
ment points, however, should be at least
10 % of the sensor range.

TAG-
No. 1
%
xx,x

Param.
TAG-
No. 1

Ad-
just-
ment

with
medium

Min-
adjust
at %

0,0

Max-
adjust
at %

100,0

Adjustment example

You know that your vessel is actually
filled up to 80%. Move to the menu
item "Max. adjust at % 100.0“. Push
the [–] key briefly, so that the figure

100.0 flashes (editing mode).

Continue pushing [–] until the figure
80.0 appears on the display. Now
push [OK] to save the adjustment.

Later, when your filling is, for exam-
ple, 10 %, go to the menu item
"Min. adjust at % 0.0“. Briefly push
[+], until the figure 0.0 flashes

(editing mode).

Continue pushing [+] until "10“ ap-
pears on the display. Now push [OK]
to save the adjustment.

You can, of course, carry out the adjustment
with medium at 0 % and 100 % filling. Note:
The figures 0 % and 100 % must flash (edit-
ing mode), before they can be saved with the
[OK] key.

Max-
adjust
at %

100,0

Max-
adjust
at %

80,0

Min-
adjust
at %

0,0

Min-
adjust
at %

10,0