VEGA VEGASON 54V…56V User Manual
Page 17
VEGASON 54V … 56V
17
Technical data
1)
Similar to DIN 16 086, references conditions acc. to IEC 770;
Temperature 15°C … 35°C; moisture 45 % … 75 %; air pressure 860 mbar … 1060 mbar
2)
The adjustment time is the time the sensor requires to output the level correctly in case of a quick level
change (with max. 10 % deviation).
Output signal
Signal output
digital output signal in two-wire technology
(VBUS): the digital output signal (meas.
signal) is modulated to the power supply and is
further processed in the signal conditioning
instrument or in the processing system
Load
resistance per signal cable max. 15
W per
wire or max. 100 m cable length
Integration time
0 … 999 seconds (adjustable in the sensor)
0 … 600 seconds (adjustable in the signal
conditioning instrument)
Display of measured values (optional)
Liquid crystal display
- in the sensor
scalable measured value output as graph and
numerical value
- powered externally by the sensor
scalable measured value output as graph and
numerical value. The display module can be
mounted up to 25 m away from the sensor.
Adjustment
- PC with adjustment software VEGA Visual Operating
- Adjustment module MINICOM
Accuracy
1)
(typical values under reference conditions, all statements relate to the nominal measuring
range)
Characteristics
linear
Deviation in characteristics including
linearity, reproducibility and
hysteresis (determined by
limit point methods)
< 0.1 %
Linearity
better than 0.05 %
Average temperature coefficient of the
zero signal
0.06 %/10 K
Resolution in general
max. 1 mm
Resolution of the output signal
0.01 % or 1 mm
Adjustment time
2)
- VEGASON 54
> 2 s (depending on parameter adjustment)
- VEGASON 55, 56
> 4 s (depending on parameter adjustment)