VEGA VEGAPULS 51V…54V User Manual
Page 21
VEGAPULS 51 V … 54 V
21
Weights
Dependent on the kind of process connection or the flange size
- Screw connection G 1
1
/
2
A, 1
1
/
2
" NPT
1,3 kg
- DN 50
6 kg
- DN 80
8 kg
- DN 100
9,5 kg
- DN 150
13,5 kg
- ANSI 2"
5,8 kg
- ANSI 3"
7 kg
- ANSI 4"
11 kg
- ANSI 6"
15,5 kg
CE-conformity
VEGAPULS series 50 radar sensors meet the protective regulations of EMC (89/336/EWG)
and NSR (73/23/EWG) and R & TTE directive (1999/5/EC).
Conformity was judged acc. to the following standards:
EN 300 683-1: 1997
EN 300 440-1: 1995
I-ETS 300-440
Expert opinion No. 0043052-01/SEE, Notified Body No. 0499
EN 61 326: 1997/A1: 1998 (EMC Emission/Susceptibility)
EN 61 010 - 1: 1993 (NSR)
EN 50 020: 1994 (ATEX)
EN 50 018: 1994
EN 50 014: 1997
Outputs and processings
Display indication
Optionally mounted, scalable analogue and digital meas. value indication as well as
additionally up to 25 m separated from the sensor, meas. value indication powered by the
sensor.
Signal output
Signal output
digital output signal in two-wire technology
(VBUS)
Two-wire technology:
The digital output signal (meas. signal) is modulated to the power supply and processed in
the signal conditioning instrument or processing system.
Technical data