VEGA VEGAPULS 51V…54V User Manual
Page 12
12
VEGAPULS 51 V … 54 V
Type code
The second figure of the type designation,
e.g. VEGAPULS 5[1]… differentiates the
instruments acc. to process connection and
antenna material.
The letter e.g. VEGAPULS 51[V]
characterizes the output signal:
V stands for a digitial output signal (VBUS), K
stands for an analogue 4 … 20 mA output
signal (compact instrument).
Types and versions - Survey
VEGAPULS 51 V EXXX X X X X X
1
for measurement in standpipe (d = 50 mm)
3
for socket lengths up to 100 mm
9
for socket lengths up to 250 mm
G - Process connection G 1
1
/
2
A
N - Process connection 1
1
/
2
NPT
K - Process connection DN 50 PN 16
L - Process connection DN 80 PN 16
E - Process connection DN 100 PN 16
F - Process connection DN 150 PN 16
S - Process connection ANSI 2"
150 PSI
W - Process connection ANSI 3"
150 PSI
P - Process connection ANSI 4"
150 PSI
V - Process connection ANSI 6"
150 PSI
Y - other process connections
X - without indication
A - with integral indication
X - without MINICOM adjustment module
B - with MINICOM adjustment module (pluggable)
A - 20 … 72 V DC; 20 … 250 V AC; 4 … 20 mA
B - 20 … 72 V DC; 20 … 250 V AC; 4 … 20 mA; HART
®
C - Two-wire (loop powered);
4 … 20 mA
D - Two-wire (loop powered);
4 … 20 mA; HART
®
E - Supply via signal conditioning instrument
P - 90 … 250 V AC (only in USA)
N - 20 … 36 V DC, 24 V AC (only in USA)
Z - Supply via signal conditioning instrument (only in USA)
.X
- FTZ approval (BRD)
EX.X
- Ex approved CENELEC EEx ia IIC T6, FTZ
.U - FCC approval (US)
EX.U - FM, CLASS 1, DIV 1; FCC (US)
K - Analogue 0 … 20 mA output signal
PULS
V - Digital output signal (two-wire technology)
for radar
Type 51: 1
1
/
2
PP or PPS/StSt rod antenna
Type 52: 1
1
/
2
PTFE or PTFE/StSt rod antenna
Type 53: DN 50 … DN 150 PTFE rod antenna
Type 54: DN 50 … DN 100 for mounting on standpipe