beautypg.com

VEGA VEGAPULS 51V…54V User Manual

Page 12

background image

12

VEGAPULS 51 V … 54 V

Type code

The second figure of the type designation,
e.g. VEGAPULS 5[1]… differentiates the
instruments acc. to process connection and
antenna material.

The letter e.g. VEGAPULS 51[V]
characterizes the output signal:
V stands for a digitial output signal (VBUS), K
stands for an analogue 4 … 20 mA output
signal (compact instrument).

Types and versions - Survey

VEGAPULS 51 V EXXX X X X X X

1

for measurement in standpipe (d = 50 mm)

3

for socket lengths up to 100 mm

9

for socket lengths up to 250 mm

G - Process connection G 1

1

/

2

A

N - Process connection 1

1

/

2

NPT

K - Process connection DN 50 PN 16
L - Process connection DN 80 PN 16
E - Process connection DN 100 PN 16
F - Process connection DN 150 PN 16
S - Process connection ANSI 2"

150 PSI

W - Process connection ANSI 3"

150 PSI

P - Process connection ANSI 4"

150 PSI

V - Process connection ANSI 6"

150 PSI

Y - other process connections

X - without indication
A - with integral indication

X - without MINICOM adjustment module
B - with MINICOM adjustment module (pluggable)

A - 20 … 72 V DC; 20 … 250 V AC; 4 … 20 mA
B - 20 … 72 V DC; 20 … 250 V AC; 4 … 20 mA; HART

®

C - Two-wire (loop powered);

4 … 20 mA

D - Two-wire (loop powered);

4 … 20 mA; HART

®

E - Supply via signal conditioning instrument
P - 90 … 250 V AC (only in USA)
N - 20 … 36 V DC, 24 V AC (only in USA)
Z - Supply via signal conditioning instrument (only in USA)

.X

- FTZ approval (BRD)

EX.X

- Ex approved CENELEC EEx ia IIC T6, FTZ

.U - FCC approval (US)

EX.U - FM, CLASS 1, DIV 1; FCC (US)

K - Analogue 0 … 20 mA output signal

PULS

V - Digital output signal (two-wire technology)

for radar

Type 51: 1

1

/

2

PP or PPS/StSt rod antenna

Type 52: 1

1

/

2

PTFE or PTFE/StSt rod antenna

Type 53: DN 50 … DN 150 PTFE rod antenna
Type 54: DN 50 … DN 100 for mounting on standpipe