beautypg.com

Configuring the diva connection, Entering the connection data – EVS IP2Archive Configurator Version 1.0 - July 2013 User Manual User Manual

Page 29

background image

4.2.3.

Configuring the DIVA Connection

Entering the Connection Data

In the Connection group box you have to enter the data Tape Storage Controller needs to
connect with Front Porch Digital's DIVArchive.

The following data has to be entered:

Manager: The name of the DIVArchive Manager. The DIVArchive Manager is the
main component in a DIVArchive system. All archive operations are controlled and
handled by the DIVArchive Manager.

Address: The IP address of the management station running the DIVArchive
Manager software component.

Port: The listening port number of the DIVArchive Manager management station. By
default, this is 9000.

A Test button allows you to test the connection with DIVArchive. If the connection is ok,
the message ‘Success’ will appear.

Otherwise, an error message will appear.

Click the Save button to save your settings. Click the Undo button to undo the
information you have just entered or modified.

Setting the Maximum Number of Archive and
Restore Requests

The Storages area allows you to the set maximum number of archive and restore requests
that will be simultaneously sent to the DIVArchive by Tape Storage Controller.

By default, 2 archive and 2 restore requests will be sent at the same time.

IP2Archive - User Manual - Configurator Version 1.0

4. Configuring Connections

25