Reference, Electrical specifications – ACU-RITE 100S User Manual
Page 31

28
100S
Turning Reference Manual
REFERENCE
Characteristic
Specification
Operating conditions
0° to 40°C (32° to 104°F)
25% to 85% relative humidity
(non-condensing)
Storage conditions
-40° to 60°C (-40° to 140°F)
25% to 85% relative humidity
(non-condensing)
100 - 240 V~
50 - 60Hz
25 VA max
Input requirements:
Voltage
Frequency
Current
Fuse
500mA, slo-blo
Position signals: channels A & B
TTL square wave signal in quadrature
(90° nominal phase relationship)
Maximum input rate: 70 kHz
Encoder input
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following
two conditions: (1) this device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired opera-
tion.
Size
9.875” x 4.679” x 4.75”
Electrical Specifications
Weight
4 lbs., 2 oz.
Mounting
Bottom; two 1/4”-20 threaded inserts
Follow these specifications when installing your
100S
system.
FCC compliance
CE compliance
For Europe
ETL compliance
ETLc compliance
For United States
For Canada