Setup scale resolution, Input 3 on/off, Position recall – ACU-RITE 100S User Manual
Page 12

100S
Turning Reference Manual
9
SETUP
Scale Resolution
To ensure accurate readings, the scale resolution shown for each axis must
correspond with the resolution of the scales on your machine.
To change the scale resolution:
•
If necessary, choose “Scale Resolution” from the Setup menu.
(Press
SETUP
and then the
ENTER
key until the screen appears).
•
Press the appropriate axis key (X, Y or Z) until the appropriate resolu-
tion appears. Choose 0.01 mm for 10µm (0.0005”) scales, 0.005 mm
for 5µm (0.0002”) and 0.001 mm for 1µm (0.00005”)scales.
•
Repeat the procedure for each axis.
•
Press
ENTER
to continue with Setup.
Input 3 On/Off
(2+ units only)
This parameter allows you to activate the third input. When this input
is enabled, Inputs 2 and 3 will be coupled on the Z-axis (both scales
will count on the Z-axis). The Input 3 scale must have the same scale
resolution as the Input 2 scale.
When Input 3 is enabled, additional parameters will need to be setup.
Refer to the procedures on pages 6-8 for setting up the Linear Error
Compensation and Count Direction Setup functions.
Position Recall
•
Set this parameter to the ON position to store the last position
of each axis when power is turned off.