Setup scale resolution, Input 3 on/off, Position recall – ACU-RITE 100S User Manual

Page 12

background image

100S

Turning Reference Manual

9

SETUP

Scale Resolution

To ensure accurate readings, the scale resolution shown for each axis must
correspond with the resolution of the scales on your machine.

To change the scale resolution:

If necessary, choose “Scale Resolution” from the Setup menu.
(Press

SETUP

and then the

ENTER

key until the screen appears).

Press the appropriate axis key (X, Y or Z) until the appropriate resolu-
tion appears. Choose 0.01 mm for 10µm (0.0005”) scales, 0.005 mm
for 5µm (0.0002”) and 0.001 mm for 1µm (0.00005”)scales.

Repeat the procedure for each axis.

Press

ENTER

to continue with Setup.

Input 3 On/Off

(2+ units only)

This parameter allows you to activate the third input. When this input
is enabled, Inputs 2 and 3 will be coupled on the Z-axis (both scales
will count on the Z-axis). The Input 3 scale must have the same scale
resolution as the Input 2 scale.
When Input 3 is enabled, additional parameters will need to be setup.
Refer to the procedures on pages 6-8 for setting up the Linear Error
Compensation and Count Direction Setup functions.

Position Recall

Set this parameter to the ON position to store the last position
of each axis when power is turned off.