Troubleshooting, Error messages (general) – ACU-RITE 100S User Manual

Page 29

background image

100S

Turning Reference Manual

26

TROUBLESHOOTING

A ROM memory error has occurred. Press the

CLEAR

key to acknowledge the error. If the system does not

operate properly, contact your

100S

distributor for

repair/replacement procedures.

A power loss has occurred. This message will appear

every time you power up the system and can be cleared

by pressing the

CLEAR

key. If the E1 message appears

at any time other than at power up, a power interruption

has occurred and your current position may be lost. Re-

establish the datum if necessary. If the problem persists,

contact your distributor for repair/replacement proce-

dures.

A random access memory (RAM) error has occurred.

Press the

CLEAR

key to acknowledge the error. If the

system does not operate properly, contact your

100S

distributor for repair/replacement procedures.

A scale miscount error (invalid waveform) has occurred.

The E9 message will appear on the axis that has the

error. Press

CLEAR

to reset the axis(es). Your current

position may be lost. Re-establish the datum if necessary.

If the system does not operate properly, contact your

100S

distributor for repair/replacement procedures.

Error Messages (General)

E1

E2

E3

E4

E9

When

100S

is powered up, it will run a series of tests to ensure that the

software is working properly. If an error message appears, refer to the
charts below for a diagnosis and solution.

An EEPROM memory error has occurred. Press the

CLEAR

key to acknowledge the error. The datum and

setup information may be lost. These areas should be

checked and reestablished upon power up. If the problem

persists, contact your distributor for repair/replacement

procedures.

This manual is related to the following products: