Troubleshooting, Error messages (general) – ACU-RITE 100S User Manual
Page 29

100S
Turning Reference Manual
26
TROUBLESHOOTING
A ROM memory error has occurred. Press the
CLEAR
key to acknowledge the error. If the system does not
operate properly, contact your
100S
distributor for
repair/replacement procedures.
A power loss has occurred. This message will appear
every time you power up the system and can be cleared
by pressing the
CLEAR
key. If the E1 message appears
at any time other than at power up, a power interruption
has occurred and your current position may be lost. Re-
establish the datum if necessary. If the problem persists,
contact your distributor for repair/replacement proce-
dures.
A random access memory (RAM) error has occurred.
Press the
CLEAR
key to acknowledge the error. If the
system does not operate properly, contact your
100S
distributor for repair/replacement procedures.
A scale miscount error (invalid waveform) has occurred.
The E9 message will appear on the axis that has the
error. Press
CLEAR
to reset the axis(es). Your current
position may be lost. Re-establish the datum if necessary.
If the system does not operate properly, contact your
100S
distributor for repair/replacement procedures.
Error Messages (General)
E1
E2
E3
E4
E9
When
100S
is powered up, it will run a series of tests to ensure that the
software is working properly. If an error message appears, refer to the
charts below for a diagnosis and solution.
An EEPROM memory error has occurred. Press the
CLEAR
key to acknowledge the error. The datum and
setup information may be lost. These areas should be
checked and reestablished upon power up. If the problem
persists, contact your distributor for repair/replacement
procedures.