• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 6 – 23

Ford Historic (OBD I) Diagnostics

6

2. Perform the following:
1) Set parking brake.
2) Transmission in park (P) or neutral (N).
3) Turn A/C off.
4) Start engine and let idle until hot.
5) Turn ignition key off.
6) Wait 10 seconds.
7) Turn key on engine off. Do not start engine.

Avoid cooling fan! It may turn on during test.

The test screen indicates the time

remaining. Do not touch vehicle or

tools during this time until the next

screen appears.

3. Toggle relays and solenoids.

Press the accelerator pedal fully to

turn ON relays and solenoids. Do

the same to turn them off. This can

be repeated as many times as

required to locate the fault.

4. Return to On Demand Test

Menu.

•Turn the ignition key off.
•Press

BACK

.

!

CAUTION

Time remaining: 2:35

Output Switch Test

Precedure runs less

than 3 minutes.

Relays & soleniods

are *Off*.

Depress release

throttle fully to

turn on.

Output Switch Test