Installation specification, 4 applications / conversion table, 5 pressure drop – STIEBEL ELTRON HDB-E Si с 01.02.2013 User Manual
Page 30: 6 fault conditions, 7 data table
![background image](/manuals/238296/30/background.png)
30
| HDB-E Si
www.stiebel-eltron.com
InStallatIOn
specification
15.4 applications / conversion table
specific electrical resistance and specific electrical
conductivity, see “data table”.
Standard
specification at 15 °C
20 °C
25 °C
Spec.
Resistance
ρ ≥
Spec.
Conductivity
σ ≤
Spec.
Resistance
ρ ≥
Spec.
Conductivity
σ ≤
Spec.
Resistance
ρ ≥
Spec.
Conductivity
σ ≤
Ωcm mS/m μS/cm
Ωcm mS/m μS/cm
Ωcm mS/m μS/cm
900
111 1111
800
125 1250
735
136 1361
1000
100 1000
890
112 1124
815
123 1227
1100
91
909
970
103 1031
895
112 1117
1200
83
833
1070
93
935
985
102 1015
1300
77
769
1175
85
851
1072
93
933
15.5 Pressure drop
pressure drop at taps at flow rate of 10 l/min
Mono-lever mixer tap. approx.
MPa
0.04 - 0.08
Thermostatic valve. approx.
MPa
0.03 - 0.05
Hand shower. approx.
MPa
0.03 - 0.15
sizing the pipework
When calculating the size of the pipework. a pressure drop for the
appliance of 0.1 MPa is recommended.
15.6 Fault conditions
In case of faults. loads up to a maximum of 95 °C at a pressure of
1.2 MPa can occur temporarily in the installation.
15.7 data table
HDB-E 12 Si
HDB-E 18 Si
HDB-E 21 Si
HDB-E 24 Si
232003
232004
232005
232006
Electrical details
Rated voltage
V
380
400
415
380
400
415
380
400
415
380
400
415
Rated output
kW
9.7
10.7
11.5
16.2
18
19.4
19
21
22.6
21.7
24
25.8
Rated current
A
14.4
15.5
16
24.7
26
27
29.5
31
32.2
33.3
35
36.3
Fuse
A
16
16
16
25
25
32
32
32
32
35
35
40
Phases
3/PE
3/PE
3/PE
3/PE
Frequency
Hz 50/60 50/60
50/- 50/60 50/60
50/- 50/60 50/60
50/- 50/60 50/60
50/-
Max. mains impedance at 50Hz
Ω
0.47
0.45
0.43
0.41
0.39
0.37
0.36
0.34
0.33
Max. mains impedance at 60 Hz
Ω
0.39
0.37
0.34
0.32
0.29
0.28
Specific resistance ρ
15
≥ (at ϕcold ≤35°C)
Ω cm ≥1100 ≥1100 ≥1200 ≥1100 ≥1100 ≥1200 ≥1100 ≥1100 ≥1200 ≥1100 ≥1100 ≥1200
Specific conductivity
σ
15
≤ (at ϕcold ≤35°C)
μS/cm
≤910
≤910
≤830
≤910
≤910
≤830
≤910
≤910
≤830
≤910
≤910
≤830
Connections
Water connection
G 1/2 A
G 1/2 A
G 1/2 A
G 1/2 A
Application limits
Max. permissible pressure
MPa
1
1
1
1
Values
Max. permissible inlet temperature
°C
35
35
35
35
ON
l/min
>2.3
>2.3
>2.3
>2.3
Flow rate for pressure drop
l/min
3.1
5.2
6.0
6.9
Pressure drop at flow rate
MPa
0.07 (0.02 without
DMB)
0.08 (0.06 without
DMB)
0.10 (0.08 without
DMB)
0.13 (0.1 without
DMB)
Flow rate limit at
l/min
4
7.5
7.5
8.5
DHW delivery
l/min
5.5
9.0
10.5
12
Δ
ϑ if presented
K
28
28
28
28
Hydraulic data
Rated capacity
l
0.4
0.4
0.4
0.4
Versions
Temperature adjustment
°C
55
55
55
55
Protection class
1
1
1
1
Insulation block
Plastic
Plastic
Plastic
Plastic
Heating system
Bare wire
Bare wire
Bare wire
Bare wire
Cap and back panel
Plastic
Plastic
Plastic
Plastic
Colour
white
white
white
white
IP-Rating
IP25
IP25
IP25
IP25
Dimensions
Height/Width/Depth
mm
470
225
117
470
225
117
470
225
117
470
225
117
Weights
Weight
kg
3.6
3.6
3.6
3.6