Note:

When this command is used without being configured with the parameter shared-key key-string for
negotiation, the default key configured using the shared-key command will be used.

2.4.3 Standby/Primary Server Switchover Interval

If you have specified the primary and standby servers in a TACACS+ server group,

the router regularly tests whether the primary server can work properly in the case

that the current server used to provide AAA services is a standby server. Once it finds

that the specified primary server can work normally, it switches from the current

standby server to the primary server. You can configure the interval for switching.

Perform the following configuration in TACACS+ view.

Table 2-4 Configure a standby/primary server switchover interval

Operation

Command

Configure a standby/primary server switchover interval

timer quiet minutes

Restore the default standby/primary server switchover
interval

undo timer quiet

The standby/primary server switchover interval defaults to five minutes.

2.4.4 Set a Shared Key for the AAA Negotiation Between Router and
TACACS+ Server

Setting a shared key can ensure the security of the communications between router

and TACACS+ server. By default, the system does not set a key. Therefore, you

should use this command to set a shared key in the case that a TACACS+ server is

used as the AAA server.

Perform the following configuration in system view.

Table 2-5 Set a shared key for the AAA negotiation between router and TACACS+ server

Operation

Command

Configure a shared key for the AAA negotiation with any
TACACS+ servers in a specified TACACS+ server group

shared-key key-string

Delete the shared key for the AAA negotiation with the
TACACS+ servers in a specified TACACS+ server group

undo shared-key

By default, no key is set.