246653-YTG-E-0108

50

Johnson Controls Unitary Products

4. Shaded RPMs require Class II blower.

TABLE 39: FAN PERFORMANCE - 40 TON

1,2

A

IRFLOW

(CFM)

A

VAILABLE

E

XTERNAL

S

TATIC

P

RESSURE

(IWG)

0.2

0.4

0.6

0.8

1.0

RPM

BHP

3

RPM

BHP

3

RPM

BHP

3

RPM

BHP

3

RPM

BHP

3

8000

304

1.4

348

1.8

393

2.2

431

2.6

469

3.0

9000

329

1.9

371

2.3

411

2.7

448

3.2

484

3.7

10000

356

2.4

396

2.8

432

3.4

467

3.9

502

4.4

11000

385

3.0

421

3.6

454

4.1

488

4.7

519

5.3

12000

414

3.9

446

4.5

479

5.0

510

5.7

539

6.2

13000

442

4.8

473

5.5

504

6.1

532

6.7

560

7.4

14000

472

6.0

502

6.6

529

7.2

556

8.0

583

8.6

15000

503

7.2

529

8.0

555

8.6

581

9.3

607

10.1

16000

532

8.7

557

9.5

583

10.2

607

10.9

631

11.8

17000

562

10.4

587

11.1

611

12.0

633

12.7

656

13.5

18000

593

12.3

616

13.1

638

13.9

660

14.7

682

15.4

A

IRFLOW

(CFM)

A

VAILABLE

E

XTERNAL

S

TATIC

P

RESSURE

(IWG)

1.2

1.4

1.6

1.8

2.0

RPM

BHP

3

RPM

BHP

3

RPM

BHP

3

RPM

BHP

3

RPM

BHP

3

8000

506

3.5

537

4.0

569

4.4

601

4.9

627

5.5

9000

518

4.2

549

4.6

581

5.1

610

5.8

637

6.3

10000

532

4.9

563

5.5

594

6.1

621

6.6

648

7.1

11000

549

5.8

579

6.4

608

7.0

634

7.6

661

8.2

12000

568

6.8

596

7.5

623

8.1

649

8.7

675

9.5

13000

588

8.0

614

8.6

640

9.3

665

10.0

690

10.7

14000

609

9.3

634

10.0

658

10.7

683

11.4

707

12.2

15000

631

10.8

655

11.6

679

12.3

702

13.1

724

13.9

16000

654

12.5

677

13.2

700

14.1

722

14.8

743

15.6

17000

678

14.3

701

15.1

722

16.0

742

16.8

763

17.6

18000

703

16.4

724

17.2

744

18.1

764

19.0

785

19.8

A

IRFLOW

(CFM)

A

VAILABLE

E

XTERNAL

S

TATIC

P

RESSURE

(IWG)

2.2

2.4

2.6

2.8

3.0

RPM

BHP

3

RPM

BHP

3

RPM

BHP

3

RPM

BHP

3

RPM

BHP

3

8000

654

6.0

681

6.5

706

7.0

729

7.6

752

8.1

9000

664

6.8

691

7.4

715

8.0

738

8.5

761

9.1

10000

675

7.8

701

8.4

725

9.0

748

9.6

771

10.2

11000

687

8.8

712

9.5

735

10.2

758

10.8

781

11.4

12000

700

10.1

723

10.7

747

11.4

770

12.2

793

12.9

13000

714

11.4

737

12.2

760

12.9

782

13.7

805

14.4

14000

729

13.0

752

13.8

774

14.5

796

15.2

817

16.0

15000

746

14.6

768

15.4

790

16.2

811

17.0

831

17.9

16000

764

16.5

786

17.3

807

18.2

826

19.0

846

19.8

17000

784

18.5

805

19.4

824

20.3

843

21.1

863

22.1

18000

805

20.7

824

21.6

843

22.6

862

23.5

881

24.5

A

IRFLOW

(CFM)

A

VAILABLE

E

XTERNAL

S

TATIC

P

RESSURE

(IWG)

3.2

3.4

3.6

3.8

4.0

RPM

BHP

3

RPM

BHP

3

RPM

BHP

3

RPM

BHP

3

RPM

BHP

3

8000

774

8.7

797

9.2

817

9.9

837

10.4

857

11.0

9000

784

9.8

806

10.3

826

10.9

846

11.6

866

12.2

10000

794

10.8

815

11.6

836

12.2

856

12.9

876

13.5

11000

804

12.2

824

12.8

845

13.5

865

14.3

886

14.9

12000

814

13.5

835

14.3

855

15.0

876

15.8

896

16.5

13000

825

15.1

846

15.9

866

16.6

886

17.4

906

18.2

14000

837

16.8

858

17.6

878

18.4

898

19.2

917

20.1

15000

851

18.7

871

19.5

891

20.4

910

21.2

928

22.1

16000

866

20.7

886

21.5

905

22.5

923

23.3

941

24.3

17000

882

23.0

901

23.8

919

24.8

937

25.7

-

-

18000

900

25.4

-

-

-

-

-

-

-

-

1.

Fan performance is based on wet evaporator coils, clean 2” throwaway filters and system/cabinet effects at standard air density and 0 feet elevation.

2.

Refer to Tables 12, 18, 23 and 42 for component additions and deductions to fan performance tables.

3.

BHP includes drive losses.