Figure 61 sip > sip settings, Table 37 sip > sip settings – ZyXEL Communications P-2602R-DxA Series User Manual
Page 124
P-2602R/RL-DxA Series User’s Guide
124
Chapter 10 Voice
Figure 61 SIP > SIP Settings
Each field is described in the following table.
Table 37 SIP > SIP Settings
LABEL
DESCRIPTION
SIP Account
Select the SIP account you want to see in this screen. If you change this field, the
screen automatically refreshes.
SIP Settings
Active SIP
Account
Select this if you want the ZyXEL Device to use this account. Clear it if you do not
want the ZyXEL Device to use this account.
Number
Enter your SIP number. In the full SIP URI, this is the part before the @ symbol.
You can use up to 127 printable ASCII characters.
SIP Local Port
Enter the ZyXEL Device’s listening port number, if your VoIP service provider gave
you one. Otherwise, keep the default value.
SIP Server
Address
Enter the IP address or domain name of the SIP server provided by your VoIP
service provider. You can use up to 95 printable ASCII characters. It does not
matter whether the SIP server is a proxy, redirect or register server.
SIP Server Port
Enter the SIP server’s listening port number, if your VoIP service provider gave you
one. Otherwise, keep the default value.
REGISTER Server
Address
Enter the IP address or domain name of the SIP register server, if your VoIP
service provider gave you one. Otherwise, enter the same address you entered in
the SIP Server Address field. You can use up to 95 printable ASCII characters.
REGISTER Server
Port
Enter the SIP register server’s listening port number, if your VoIP service provider
gave you one. Otherwise, enter the same port number you entered in the SIP
Server Port field.