Multi filter, Freeze, Effects parameters – Yamaha DM2000 User Manual
Page 325: One input, one output basic sampler
Effects Parameters
325
DM2000—Owner’s Manual
MULTI FILTER
Two input, two output 3-band multi-filter (24 dB/octave).
FREEZE
One input, one output basic sampler.
Parameter
Range
Description
TYPE 1
HPF, LPF, BPF
Filter 1 type: high pass, low pass, band pass
TYPE 2
HPF, LPF, BPF
Filter 2 type: high pass, low pass, band pass
TYPE 3
HPF, LPF, BPF
Filter 3 type: high pass, low pass, band pass
FREQ. 1
28.0 Hz–16.0 kHz
Filter 1 frequency
FREQ. 2
28.0 Hz–16.0 kHz
Filter 2 frequency
FREQ. 3
28.0 Hz–16.0 kHz
Filter 3 frequency
LEVEL 1
0–100
Filter 1 level
LEVEL 2
0–100
Filter 2 level
LEVEL 3
0–100
Filter 3 level
RESO. 1
0–20
Filter 1 resonance
RESO. 2
0–20
Filter 2 resonance
RESO. 3
0–20
Filter 3 resonance
Parameter
Range
Description
REC MODE
MANUAL, INPUT
In MANUAL mode, recording is started by pressing the REC and
PLAY buttons. In INPUT mode, Record-Ready mode is engaged by
pressing the REC button, and actual recording is triggered by the
input signal.
REC DLY
–1000 to +1000 ms
Recording delay. For plus values, recording starts after the trigger is
received. For minus values, recording starts before the trigger is
received.
TRG LVL
–60 to 0 dB
Input trigger level (i.e., the signal level required to trigger recording
or playback)
TRG MASK
0–1000 ms
Once playback has been triggered, subsequent triggers are ignored
for the duration of the TRG MASK time.
PLY MODE
MOMENT, CONTI.,
INPUT
In MOMENT mode, the sample plays only while the that the PLAY
button is pressed. In CONT mode, playback continues once the
PLAY button has been pressed. The number of times the sample
plays is set using the LOOP NUM parameter. In INPUT mode, play-
back is triggered by the input signal.
START
1
1. 0.0–5941.0 ms (fs=44.1 kHz), 0.0 ms–5458.3 ms (fs=48 kHz), 0.0–2970.5 ms (fs=88.2 kHz),
0.0 ms–2729.2 ms (fs=96 kHz)
Playback start point in milliseconds
END
1
Playback end point in milliseconds
LOOP
1
Loop start point in milliseconds
LOOP
NUM
0–100
Number of times the sample plays
START
[SAMPLE]
0–262000
Playback start point in samples
END
[SAMPLE]
0–262000
Playback end point in samples
LOOP
[SAMPLE]
0–262000
Loop start point in samples
PITCH
–12 to +12 semitones
Playback pitch shift
FINE
–50 to +50 cents
Playback pitch shift fine
MIDI TRG
OFF, C1–C6, ALL
PLAY button can be triggered by using MIDI Note on/off messages.