Unisys E-@CTION EFP9800 User Manual
Page 150

EFP9800 ESC/POS Commands
6– 60
3255
4073– 002
n = 3: Error Status
Error
Status
Bit Description
0
1
0
Not Used
Always 0
1
Not Used
Always 1
2
Mechanical Error
No Error
Error
3 Undefined
4
Not Used
Always 1
5
Unrecoverable Error
No Error
Error
6-7
Not Used
Always 0
Note: For Bit 2, mechanical errors include home position detection,
carriage detection, and slip ejection errors. If the error is due to a
paper jam or similar condition, the printer can be recovered with
DLE ENQ
n (1
≤
n
≥
2) after the jam is cleared. If the error is due to a
circuit failure (i.e., a wire break), the printer cannot be recovered.
n = 4: Receipt/Journal Paper Out Switch Status
Receipt/Journal Paper Out Switch Status
Bit
Receipt/Journal Paper Out Switch
0
1
0
Not Used
Always 0
1
Not Used
Always 1
2
Journal Paper Near End
Paper Low Not Detected
Paper Low Detected
3
Journal Paper Near End
Paper Low Not Detected
Paper Low Detected
4
Not Used
Always 1
5-6 Undefined
7
Not Used
Always 0