TANDBERG Gatekeeper/Border Controller API D14172.01 User Manual
Page 47

TANDBERG Gatekeeper/Border Controller API User Guide
D14172.01
page 47 of 84
Pipes Pipe [1..100] Bandwidth Total Limit: <1..100000000>
If this pipe has limited bandwidth, sets the maximum bandwidth (in kbps) available at any
one time on the pipe.
Pipes Pipe [1..100] Bandwidth PerCall Mode:
Determines whether or not this pipe is limiting the bandwidth of individual calls. None: no
bandwidth available.
Pipes Pipe [1..100] Bandwidth PerCall Limit: <1..100000000>
If this pipe has limited per-call bandwidth, sets the maximum amount of bandwidth (in kbps)
available for any one call.
Links Link [1..100] Name:
Assigns a name to this link.
Links Link [1..100] Node1 Name:
Specifies the first zone or subzone to which this link will be applied.
Links Link [1..100] Node2 Name:
Specifies the second zone or subzone to which this link will be applied.
Links Link [1..100] Pipe1 Name:
Specifies the first pipe to be associated with this link.
Links Link [1..100] Pipe2 Name:
Specifies the second pipe to be associated with this link.
Services CallTransfer Mode:
Controls whether or not third party call transfer is enabled.
Note: The Gatekeeper must be operating in call routed mode in order for calls to be
transfered.
Services AdHocConferencing Mode:
Controls whether or not Multiway is enabled.
Services AdHocConferencing ID:
Specifies the unique 3-digit ID for this system. This ID is used by the MCU to distinguish
between conference requests from different gatekeepers.
Services AdHocConferencing Prefix:
Specifies the prefix to be used for unencrypted conference requests.
Services AdHocConferencing Encryption Prefix:
Specifies the prefix to be used for encrypted conference requests.