beautypg.com

Toshiba E-STUDIO 210C User Manual

Page 166

background image

1

2

3

4

5

6

7

8

9

10

11

12

9-24

WHEN THE GRAPHIC SYMBOLS FLASH ON THE TOUCH PANEL

3

Pull out the grip of the saddle stitch holder ( ) to-

ward you and turn it ( ) 90

o

clockwise in the direc-

tion of the arrow.

4

Remove the empty staple case and set a new one.

- Replace both staple cases with new ones.

- Do not remove the seal holding the staples before the staple

case is set in the cartridge.

5

Return the saddle stitch holder and the saddle

stitching unit to their respective original positions.

6

Make sure that the finisher is attached to the copier

firmly and that A3, B4 or A4-R size paper is set in

the copier.

- If one of the above paper sizes is not set, test stapling cannot

be performed.

If test stapling fails to be performed and the following mes-
sage remains displayed, repeat the above procedure from
steps 1 to 7.

Set staple cartridge

2

Slide out the saddle stitch unit carefully toward the

front.

7

Close the lower cover of the finisher. Test stapling

is then automatically performed on a blank sheet.

- This operation is carried out to avoid empty stitching.

6. ADDING STAPLES (OPTIONAL) (Cont.)