Toshiba TEC B-419-GS10-QQ User Manual
Page 30
2. PRINTER SETUP
EO1-33030
2.10 Program Download
2- 20
2.10.3 Firmware Files Copy
(Cont.)
8.
If it is necessary to change any of the communication parameters,
select the Settings (S) drop down menu and then select Conditions
(S) as shown in the figure below.
9.
The communications setting window will appear as in figure below
to allow you to change the communication parameters. Set the
proper settings for Device, Parity, and Baud Rate, and click on
OK
button.
10.
In the Settings drop down menu is another possible selection
labeled Comment (C ) as shown below. If Comment (C) is
selected then the comment selection menu appears. There are three
different settings that can be selected in this operation, Nothing,
Only Date, and Enter Some Comments. If nothing is selected no
comment is attached. If Only date is selected, then the PC date
will be attached as the message. If Enter Some Comments is
selected, a comment message of up to 16 characters can be
attached to the download, and will appear on the diagnostic
printout.
NOTE:
1. The communications
settings should be set as
follows.
Download:
9600 bps to 115200 bps,
None parity
Sensor setting:
19200 bps, None parity
Printer information
registration:
19200 bps, None parity
Test Print:
19200 bps, None parity
2. The settings shown on the
display are the default.
NOTE:
This procedure is only used by
service personnel to download
a message along with the
firmware download. Be sure
to select Nothing.