FUNCTIONS MENU

Functions Menu

INSTRUMENT ADJUSTMENTS

To enter or exit program mode: Press

▲ ▼ together for 3 seconds

To scroll through functions: Press

▲ or ▼

To change levels or options: Press

✱ ▲ together or ✱ ▼ together

To view setpoint:

Press ✱

To increase setpoint:

Press ✱ ▲ together

To decrease setpoint:

Press ✱ ▼ together

To reset an alarm or fault condition:

Press ▲ ▼ together briefly

Notes: If in difficulty by becoming “lost” in program mode, press ▲ and ▼

together for 3 seconds to return to display mode, check the

INSTRUMENT ADJUSTMENTS above and try again.

When in program mode, after 60 seconds of key inactivity

the display will revert to either

or, if the initial configuration has been completed, the

measured value. Any settings already completed will be retained.

Setpoint 1

Output

indicator

(green)

Process temperature (PV) or Function (green)

Setpoint temperature (SP) or Option (orange)

Setpoint 2 Output indicator (red)

BAND

INT.T

DER.T

DAC

CYC.T

OFST

SP.LK

SPRR

SPRN

SOAK

SET.2

BND.2

CYC.2

LEVL 1

TUNE

Autotune or Park

oFF

; on; tunE; ParK; At.Sp

SP1 Prop band (gain)/hyst

0.1 deg to 25% sensor f/s

(10°C/18°F

)

Integral time (reset)

Off; 0.1 to 60 min (

5 min

)

Derivative time (rate)

Off; 1 to 200 sec (

25 sec

)

Derivative approach

0.5 to 5.0 x bAnd (

1.5

)

Cycle time or on/off

On.off; 0.1 to 81 sec

(20 sec

)

Offset (manual reset)

0 to 50% x bAnd

(In.t = off

)

Setpoint lock (SP1)

Off

; on

Setpoint Ramp rate

0 to 9990 deg/hour

Ramp off/on

On;

off

; hold

Soak time

Off

; 0 to 1440 min

Adjust SP2 setpoint

+/– sensor full scale or

full scale

SP2 prop band/Gain/Hyst

0.1 deg to 100% sensor

f/s

(2°C/3.6°F)

SP2 Cycle on/off

On.off

; 0.1 to 81 sec

S P 1 S E T T I N G S

BAUD

DATA

DBUG

LEVL C

ADDR

Instrument address

0 to 255

Baud rate

1200: 2400: 4800:

9600

: 19k2

Data format

18n1

:18E1:18O1

Tx/Rx activity

Off

; on

C O M M S S E T T I N G S

P R O G R A M M E R S E T T I N G S

S P 2 S E T T I N G S

HAND

PL.1

PL.2

SP2.A

SP2.B

DISP

HI.SC

LO.SC

INPT

UNIT

LEVL 2

SP1.P

Read SP1 output %

0 to 100% read only

SP1 manual output %

0 to 100% proportional

mode only

Limit SP1 output %

100

to 0%

Limit SP2 output %

100

to 0%

Main SP2 mode

nonE

; dV

.hi; dV

.Lo; bAnd;

FS.hi; FS,Lo; Cool

Second SP2 mode

nonE

; LtCH; hold; Lt.ho;

nLin

Display resolution

1 or 0.1 degree

Set scale maximum

0.0

Sensor max to

sensor full scale

Set scale minimum

0.0

Sensor min to sensor

full scale

Select input sensor

nonE

Select display units

nonE

; °C; °F; bAr;

PSi; Ph; rh; SEt

M A N U A L A D J U S T M E N T S

S P 2 M O D E S

R A N G I N G

C O N F I G U R E I N P U T

SP2.D

BURN

REU.D

REU.L

SPAN

ZERO

CHEK

READ

TECH

UER

RSET

LEVL 3

SP1.D

SP1 output device

nonE

; rlY

; SSd

*

SP2 output device

nonE

; SSd; rlY

(read only)

*

Sensor burn-out

uP

.SC

; dn.SC; 1u.2d; 1d.2u

Reverse outputs

1r.2d

; 1d.2d; 1r

.2r; 1d.2r

Reverse O/P LEDs

1n.2n

; 1i.2n; 1n.2i; 1i.2i

Span adjustment

0.0

to 25% sensor f/s

Zero Adjustment

0.0

to 25%

sensor full scale

Set Monitor

Off

; on

Read Monitor

VAr; hi; lo deg

Read T

une Data

CtA; Ctb; Ct1; Ct2; Ct3;

Ct4; oS1; uS; oS2

Software version

Consult unit

RESET

nonE

; ALL

C O N F I G U R E O U T P U T

S A F E T Y S E T T I N G S

C A L I B R A T I O N

P E R F O R M A N C E D A T A

PROG

NO.AL

DIS.S

DER.S

LEVL 4

LOCK

Security lock

nonE

; LEV 3; LEV 2; ALL

Disable program auto-exit

Auto

; StA

Y

Disable -AL- alarm display

Off

; on

Display averaging

dir

; 1 to 32 (

6)

Derivative sensitivity

0.1 to 1.0 x dEr

.t (

0.5

)

U S E R - P R O T E C T E D S E T T I N G S

PROGRAM ENTRY

Level C only visable

when COMMS
Option fitted

QUICK START ENTRY

KEY

▼ ▲

TO VIEW FUNCTIONS

KEY

✱ ▼

OR

✱ ▲

TOGETHER TO CHANGE LEVELS OR OPTIONS

Range of Adjustment shown in

red

under

description. If applicable, factory settings shown
in

bold

.

*

Note:

Dual Relay and Dual SSd Output Options

Models CN9411 and CN9422 have their outputs
pre-configured. (see page 22)

A3

INPT

NONE