beautypg.com

Sensor selection, Input/sensor selection – Omega Engineering CN9400 User Manual

Page 35

background image

Sensor Selection

Option/Sensor type

Sensor range

Linearity

Thermocouples

tc b

B

0 to 1800 °C

32 to 3272 F

Pt-30%Rh/Pt-6%Rh

2.0 *

tc E

E

0 to 600 °C

32 to 1112 F

Chromel/Con

0.5

tc J

J

0 to 800 °C

32 to 1472 F

Iron/Constantan

0.5

tc K

K

-50 to 1200 °C

-58 to 2192 F

Chromel/Alumel

0.25*

tc L

L

0 to 800 °C

32 to 1472 F

Fe/Konst

0.5

tc n

N

-50 to 1200 °C

-58 to 2192 F

NiCrosil/NiSil

0.25*

tc r

R

0 to 1600 °C

32 to 2912 F

Pt-13%Rh/Pt

2.0*

tc s

S

0 to 1600 °C

32 to 2912 F

Pt-10%Rh/Pt

2.0*

tc t

T

-200 / 250 °C

-273 / 482 F

Copper/Con

0.25*

Resistance thermometer

rtd

-200 / 400 C

-273 / 752 F

Pt100/RTD-2

0.25*

Linear process inputs (Input mV range: 0 to 50mV)

Displays

0 - 20mV

4 - 20mV

setpoint limits

Lin1

0 - 100

0 - 400

± 0.5%

Lin2

0 - 100

-25 - 400

± 0.5%

Lin3

0 - 1000

0 - 3000

± 0.5%

Lin4

0 - 1000

-250 - 3000

± 0.5%

Lin5

0 - 2000

0 - 3000

± 0.5%

Notes: 1 Linearity: 5-95% sensor range

2 * Linearity B:5° (70º - 500°C) K/N:1° >350°C exceptions: R/S: 5°<300°C T:1° <- -25° >150°C RTD/Pt100: 0.5° <-100°C

SENSOR SELECTION