beautypg.com

Function list – Omega Engineering CN9400 User Manual

Page 24

background image

Function List

F

unction Options

[Factory settings] shown in brackets

Select SP1/2 LED indicator modes

SP1

SP2

[1n.2n]

Normal

Normal

1i.2n

Invert

Normal

1n.2i

Normal

Invert

1i.2i

Invert

Invert

[0.0] to ±25% sensor maximum

Sensor span adjust

For recalibrating to a remote standard e.g. External

Meter, data logger. See ADVANCED SETTINGS page

24,25.

[0.0] to ±25% sensor f/s

Zero sensor error, see SPAn

[oFF] on

Select control accuracy monitor

[

Var] hi Lo

Read control accuracy monitor

20

LEVEL 3 (continued)

F

unction Options

[Factory settings] shown in brackets

[

Ct A] CT b Ct 1 Ct 2 Ct 3

Ct 4 oS 1 uS oS 2

Read Autotune tuning cycle data (see figure, page 14)

Software version number

[nonE] ALL

Resets all functions to factory settings

Caution:

Note current configuration before using this

function, otherwise initial configuration and

OEM settings must be re-entered.

REU.L

TECH

VER

RSET

SPAN

ZERO

CHEK

READ